DOI 10.1097/j.jcrs.0000000000001715

Медицинская библиотека · Journal of cataract and refractive surgery · 2025

Comparison of intraocular lens formula accuracy for eyes with prior scleral buckle surgery.

Kong Alan W, Jeon Michelle J, Lin Shawn R, Bartlett John D, McCannel Colin A, Hoffer Kenneth J, Savini Giacomo, Nejad Mitra

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To compare intraocular lens (IOL) formula prediction accuracy for patients with previous scleral buckling surgery.

SETTING

Single academic center in Los Angeles, California.

DESIGN

Retrospective study.

METHODS

Patients who had cataract extraction after scleral buckle surgery from 2014 to 2024 were included. The spherical equivalent prediction error (SEQ-PE) from Barrett Universal II (BUII), Hoffer QST, Holladay 1, Kane, Radial Basis Function (RBF) 3.0, and SRK/T was evaluated. The Wang-Koch-adjusted axial lengths were used for eyes >25.0 mm for the Holladay 1 and SRK/T formulas. Analysis was performed with Eyetemis, an online software designed to compare the accuracy, precision, and trueness of the SEQ-PE.

RESULTS

79 eyes from 77 patients were included. The 6 formulas showed similar accuracy, with no statistically significant differences for pairwise comparisons of the absolute SEQ-PE, which ranged between 0.33 diopters (D) (±0.52 D) for the Holladay 1 and 0.42 D (±0.56 D) for the RBF 3.0 formulas, and for pairwise comparisons of the precision of SEQ-PE, except for the comparison between BUII and Hoffer QST. There was no significant difference in the absolute SEQ-PE within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 D. Comparing the trueness of the SEQ-PE, BUII and Hoffer QST were hyperopic, while Holladay 1 and SRK/T were myopic.

CONCLUSIONS

The formulas compared had similar accuracy of the absolute and precision SEQ-PE for eyes with scleral buckles. There was variability in the trueness of the 6 formulas, however. Therefore, surgeons should consider these trends for IOL selection in eyes with scleral buckles.

Для цитирования: Kong Alan W, Jeon Michelle J, Lin Shawn R, Bartlett John D, McCannel Colin A, Hoffer Kenneth J, Savini Giacomo, Nejad Mitra. Comparison of intraocular lens formula accuracy for eyes with prior scleral buckle surgery.. Journal of cataract and refractive surgery. 2025. DOI: 10.1097/j.jcrs.0000000000001715.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.