MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0971-9784.197824

Медицинская библиотека · Annals of cardiac anaesthesia · 2017

Selection of an appropriate left-sided double-lumen tube size for one-lung ventilation among Asians.

Ideris Siti Salwani, Che Hassan Muhamad Rahimi, Abdul Rahman Mohd Ramzisham, Ooi Joanna Su Min

СтатьяПеревод пока не подготовлен

Аннотация

CONTEXT: Selecting an appropriate size double-lumen tube (DLT) for one-lung ventilation has always been a challenge as most choose it based on experience or using the existing guidelines based on gender and height.

AIMS: The aim of this study was to determine if the appropriate choice of this tube could be based on the patients' height, weight, tracheal diameter (TD), or the left main stem bronchus diameter (LMBD) and also to determine the relationship between height and depth of insertion among Asians.

SUBJECTS AND

METHODS

This was a retrospective review of 179 patients who were intubated with a left-sided DLT and also had a posterior-anterior view of a digital chest radiograph for tracheal and left main bronchus diameter measurements. Additional data collected included patients' demographics and DLT size used.

RESULTS

There were 123 (68.7%) males and 56 (31.3%) females with an overall mean age of 33.3 ± 16.3 years. Majority of the males (48.8%) used a size 39 Fr while females (46.4%) used a 35 Fr. There were weak correlations between DLT size with height (male: R2 = 0.222; female: R2 = 0.193), DLT size with weight (male: R2 = 0.109; female: R2 = 0.211), DLT size with TD (male: R2 = 0.027); female: R2 = 0.016), and DLT size with LMBD (male: R2 = 0.222; female: R2 = 0.193). There was a good correlation between depth of DLT inserted with patient's height for both genders.

CONCLUSION

The appropriate size of the left-sided DLT could not be predicted based on patients' height, weight, tracheal or left main bronchus diameter alone in Asians; however, the depth of insertion of the tube was dependent on the height in both genders.

Для цитирования: Ideris Siti Salwani, Che Hassan Muhamad Rahimi, Abdul Rahman Mohd Ramzisham, Ooi Joanna Su Min. Selection of an appropriate left-sided double-lumen tube size for one-lung ventilation among Asians.. Annals of cardiac anaesthesia. 2017. DOI: 10.4103/0971-9784.197824.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.