m+Medelevator.RU
← Поиск публикаций
Haemophilia : the official journal of the World Federation of Hemophilia · 2023

Whole F8 gene sequencing combined with splicing functional analyses led to a substantial increase of the molecular diagnosis yield for non-severe haemophilia A.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dericquebourg Amy, Fretigny Mathilde, Leuci Alexandre, Zawadzki Christophe, Huguenin Yoann, Castet Sabine-Marie, Dargaud Yesim, Vinciguerra Christine, Jourdy Yohann

Аннотация

INTRODUCTION: Conventional genetic investigation fails to identify the F8 causal variant in 2.5%-10% of haemophilia A (HA) patients with non-severe phenotypes. In these cases, F8 deep intronic variants could be causal.

AIM: To identify pathogenic F8 deep intronic variants in genetically unresolved families with non-severe HA analysed in the haematology laboratory of the Hospices Civils de Lyon.

METHODS: The whole F8 was analysed by next generation sequencing. The pathogenic impact of candidate variants identified was assessed using both in silico analysis (MaxEntScan and spliceAI) and functional analysis (RNA or minigene assay).

RESULTS: Sequencing was performed in 49/55 families included for which a DNA sample from a male propositus was available. In total, 33 candidate variants from 43 propositi were identified. These variants corresponded to 31 single nucleotide substitutions, one 173-bp deletion, and an 869-bp tandem triplication. No candidate variant was found in six propositi. The most frequent variants found were the association of [c.2113+1154G>C and c.5374-304C>T], identified in five propositi, and the c.2114-6529C>G identified in nine propositi. Four variants had been previously described as HA-causing. Splicing functional assay found a deleterious impact for 11 substitutions (c.671-94G>A, c.788-312A>G, c.2113+1154G>C, c.2114-6529C>G, c.5999-820A>T, c.5999-786C>A, c.5999-669G>T, c.5999-669G>A, c.5999-669G>C, c.6900+4104A>C, and c.6901-2992A>G). The HA-causing variant was identified in 33/49 (67%) cases. In total, F8 deep intronic variants caused 8.8% of the non-severe HA among the 1643 families analysed in our laboratory.

CONCLUSION: The results emphasise the value of whole F8 gene sequencing combined with splicing functional analyses to improve the diagnosis yield for non-severe HA.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты