Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 1991

Color flow Doppler mapping studies of "physiologic" pulmonary and tricuspid regurgitation: evidence for true regurgitation as opposed to a valve closing volume.

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Maciel B C, Simpson I A, Valdes-Cruz L M, Recusani F, Hoit B, Dalton N, Weintraub R, Sahn D J

Аннотация

Color flow Doppler mapping using either an Aloka 880 or a Toshiba SSH65A system was performed in 39 normal subjects (aged 13 to 45 years) and 43 patients (aged 13 to 82 years) with pathologic tricuspid or pulmonary regurgitation to evaluate the incidence of "physiologic" regurgitation of right heart valves and to determine the differentiating characteristics in the spatial distribution and velocity encoding of "normal" and "pathologic" regurgitant jets. In the normal subjects, tricuspid and pulmonary regurgitation were documented in 32 (83%) and 36 (93%), respectively, and were unrelated to the system being used. Flow acceleration and aliasing were imaged on the right ventricular side of the tricuspid regurgitant orifice and on the pulmonary artery side of the pulmonary valve (in both normal subjects and patients), and indicated flow convergence for true regurgitation through an orifice as opposed to blood being driven retrogradely by the closing valve. Such proximal acceleration was documented in all patients with pathologic tricuspid regurgitation, in 31/32 of the normal subjects with tricuspid regurgitation, and was also observed in 12/15 (80%) of the patients and 4/12 (33%) of normal subjects with pulmonary regurgitation who were examined with the Toshiba system. The dimensions (mean +/- SD) of tricuspid regurgitant jets (length [JL] and area [JA]) were consistently larger in the patients than in the normal subjects [JL: 3.4 +/- 0.9 vs 1.2 +/- 0.5 cm, p less than 0.001; and JA: 5.7 +/- 2.0 vs 1.4 +/- 0.7 cm2, p less than 0.001) as were the pulmonary regurgitation jet dimensions (JL: 1.8 +/- 0.4 vs 0.9 +/- 0.08 cm, p less than 0.001; JA: 1.8 +/- 0.7 vs 0.3 +/- 0.08 cm2, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты