MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2003.08.035

Медицинская библиотека · Journal of cataract and refractive surgery · 2004

Laser in situ keratomileusis for the correction of residual ametropia after penetrating keratoplasty.

Buzard Kurt, Febbraro Jean-Luc, Fundingsland Bradley R

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety, efficacy, and predictability of excimer laser in situ keratomileusis (LASIK) to correct residual myopia and astigmatism after penetrating keratoplasty (PKP).

SETTING

Buzard Eye Institute, Las Vegas, Nevada, USA.

METHODS

Twenty-six eyes had LASIK at least 1 year after PKP. All eyes were followed for at least 6 months after LASIK; 22 eyes were followed for 12 months. Sutures were removed at a mean of 13 months post PKP. Laser in situ keratomileusis was performed with the Chiron Automated Corneal Shaper microkeratome (Bausch & Lomb) and the Visx Star excimer laser. Before LASIK, the mean spherical equivalent (SE) was -4.94 diopters (D) +/- 2.79 (SD) and the mean astigmatism was 2.71 +/- 2.33 D; all eyes had regular astigmatism or slightly decentered, irregular astigmatism.

RESULTS

At the last follow-up, the mean postoperative uncorrected visual acuity (UCVA) was 20/30, the mean SE was -0.35 +/- 0.65 D, and the mean residual astigmatism was 1.06 +/- 0.67 D. Eighty-six percent of patients had an SE within +/-1.00 D of emmetropia and a UCVA of 20/40 or better. Ten eyes (39%) had 1 or more enhancements, which were performed a mean of 6 months after the primary LASIK. Significant complications such as wound dehiscence, epithelial ingrowth, and corneal decompensation did not occur. At the last follow-up, 18% of patients lost 1 line of best corrected visual acuity and 27% gained 1 line.

CONCLUSION

Laser in situ keratomileusis appeared to be a reliable and safe procedure to correct residual myopia and astigmatism after PKP.

Для цитирования: Buzard Kurt, Febbraro Jean-Luc, Fundingsland Bradley R. Laser in situ keratomileusis for the correction of residual ametropia after penetrating keratoplasty.. Journal of cataract and refractive surgery. 2004. DOI: 10.1016/j.jcrs.2003.08.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.