MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14715/cmb/2022.68.3.29

Медицинская библиотека · Cellular and molecular biology (Noisy-le-Grand, France) · 2022

Usage of Yb(OH)CO3 Nanoparticles-based Computed Tomography Image in the Prediction Model of Lung Biopsy Pneumothorax.

Hu Wei, Hu Jing, Guo Wei, Chen Jun, Liang Shuang, Qian Wei, Yuan Xi

СтатьяПеревод пока не подготовлен

Аннотация

This study aimed to explore the application of Yb(OH)CO3 nanoparticles in the prediction model of computed tomography (CT) contrast lung biopsy pneumothorax (LBP) by synthesizing a new type of Yb(OH)CO3 nanoparticles, which provides a basis for clinical application. Yb(OH)CO3 nanoparticles were prepared by a homogeneous precipitation process based on urea, and the samples were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Methyl thiazolyl tetrazolium (MTT) assay was adopted in vitro cytotoxicity test, optical density (OD) value was measured with a microplate reader at a wavelength of 570 nm, the cell viability was analyzed, and the cytomorphological changes were observed with an optical microscope. Besides, 40 selected patients with CT-guided percutaneous needling biopsy (PTNB) were rolled into a control group and an observation group. A pneumothorax prediction model was constructed under the support vector machine (SVM) model. The accuracy, sensitivity, and specificity of SVM for pneumothorax prediction were 88.7%, 71.3%, and 100%, respectively; while those of CT imaging with Yb(OH)CO3 nanoparticles were 96.7%, 84.3%, and 100%, respectively. Mean squared errors (MESs) of Yb(OH)CO3 nanoparticles-based CT contrast agent and conventional contrast agent were 14,532 and 7,021, respectively, and mutual information (MI) was 0.1232 and 0.2354, respectively, so the difference between the two groups was significant (P < 0.05). In summary, Yb(OH)CO3 nanoparticles-based CT contrast agents showed good histocompatibility and low toxicity, and the Yb(OH)CO3 nanoparticles-based CT images showed high accuracy in the prediction of LBP.

Для цитирования: Hu Wei, Hu Jing, Guo Wei, Chen Jun, Liang Shuang, Qian Wei, Yuan Xi. Usage of Yb(OH)CO3 Nanoparticles-based Computed Tomography Image in the Prediction Model of Lung Biopsy Pneumothorax.. Cellular and molecular biology (Noisy-le-Grand, France). 2022. DOI: 10.14715/cmb/2022.68.3.29.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.