Complications of cardiac resynchronization therapy implantation: De novo implants versus upgrades.

Grymuza Maciej, Katarzyńska-Szymańska Agnieszka, Chmielewska-Michalak Lidia, Waśniewski Michał, Ochotny Romuald, Lesiak Maciej, Mitkowski Przemysław

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac resynchronization therapy (CRT) is a well-established treatment of patients with advanced heart failure and electrical dyssynchrony. Implantation of those devices is in some cases associated with intervention on a formerly implanted system. The aim of this analysis was to compare the rate and type of complications of de novo implants and upgrades to CRT-D.

METHODS

Retrospective data were collected from medical records, including 326 patients treated with CRT-D between 2015 and 2020. The following data were analyzed: procedure data including complications, demographics, co-morbidities, pharmacotherapy, and laboratory tests. The primary endpoint of the study was all-cause mortality.

RESULTS

A total of 326 procedure were included, of which 53% (n = 172) were de novo implants and 47% (n = 154) were upgrades. The groups did not differ in the incidence of complications: in the de novo group: 25.5% (n = 44); in the upgrade group: 30.5% (n = 47), p = 0.78. The incidence of complications was also similar in respect of the following: early (p = 0.98) and late (p = 0.45), infectious (p = 0.38) and non-infectious (p = 0.82), surgical (p = 0.38) and device or lead related (p = 0.6). The most common complication in the upgrade group was pocket hematoma (n = 9, 5.8%) and in the de novo group pneumothorax (n = 8, 4.7%).

CONCLUSIONS

Upgrade procedures of are not associated with a higher percentage of complications than de novo implantations of CRT-D. Previously implanted cardiac implantable electronic device should not limit the implantation of CRT-Ds.

Для цитирования: Grymuza Maciej, Katarzyńska-Szymańska Agnieszka, Chmielewska-Michalak Lidia, Waśniewski Michał, Ochotny Romuald, Lesiak Maciej, Mitkowski Przemysław. Complications of cardiac resynchronization therapy implantation: De novo implants versus upgrades.. Cardiology journal. 2022. DOI: 10.5603/cj.a2022.0057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.