MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rti.0000000000000636

Медицинская библиотека · Journal of thoracic imaging · 2022

Quantification of Pneumothorax Volume on Chest X-Ray: A More Accurate Index Based On Measurements Made With 3D-printed Models.

Aguinagalde Borja, Zabaleta Jon, López Iker, Izquierdo Jose M, Mendoza Mikel, Garmendia Eñaut, Fernandez-Monge Arantza, Lizarbe Jon A

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Owing to the extent of lung collapse estimated on chest radiograph it is still the complementary test most commonly used in the management of patients with pneumothorax. There are several indices to assess the extent of lung collapse. The objective of this study was to develop a more accurate index, using the 3D printing technology.

MATERIALS AND

METHODS

We created physical hemithorax models using 3D printing. In this way, we obtained simple radiographs of models for which the lung volume was known accurately. In the first part of the study, we estimated the intraobserver and interobserver agreement as well as the agreement between methods. We created 2 new indices and the results obtained with these; the Light index and the Collins method were compared with data on real lung volume loss using linear regression analysis and by calculating the coefficient of determination (r2). In the second part of the study, we validated the 4 equations, comparing the Light index, the Collins method, and the 2 new indices using regression analysis. For this analysis, we used STATA V14.

RESULTS

Both intraobserver and interobserver agreements were very high (<0.9). The agreement between the Collins method and the Light index was poor, with a mean difference of 18.6%. The equation that best represented real lung collapse was the new equation 2.

CONCLUSIONS

This study demonstrates the poor agreement between the Light index and Collins method for measuring the extent of lung collapse in pneumothorax and proposes a more accurate equation for this measurement based on a simple chest radiograph.

Для цитирования: Aguinagalde Borja, Zabaleta Jon, López Iker, Izquierdo Jose M, Mendoza Mikel, Garmendia Eñaut, Fernandez-Monge Arantza, Lizarbe Jon A. Quantification of Pneumothorax Volume on Chest X-Ray: A More Accurate Index Based On Measurements Made With 3D-printed Models.. Journal of thoracic imaging. 2022. DOI: 10.1097/rti.0000000000000636.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.