m+Medelevator.RU
← Поиск публикаций
Echocardiography (Mount Kisco, N.Y.) · 2018

Mitral leaflet separation to evaluate the severity of mitral stenosis: Validation of the index by transesophageal three-dimensional echocardiography.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bigdelu Leila, Poorzand Hoorak, Azari Ali, Jarahi Lida, Ghaderi Fereshteh, Fazlinejad Afsoon, Alimi Hedieh, Rohani Atooshe, Manavifar Negar

Аннотация

BACKGROUND: Determining severity of mitral stenosis (MS) by planimetry of mitral valve orifice area (MVA) has been a challenging issue in clinical practice, especially for less experienced cardiologists. Mitral leaflet separation (MLS) has shown a good correlation with MVA measurements. However, it has never been validated against multiplane 3DTEE planimetry (MVA3D ). We aimed to evaluate the accuracy of MLS index (MLSI2D ) in predicting MS severity.

METHODS: We prospectively enrolled 144 patients with MS who underwent clinically indicated 2DTTE and 3DTEE. MLSI2D was yield by averaging the maximal leaflet tip distance in diastole, in parasternal long-axis and apical four-chamber views. MVA3D was used as the reference method.

RESULTS: MLSI2D showed an excellent discriminatory ability between different grades of MS (P < .001). There was a significant positive correlation between MLSI2D and MVA3D (r = .93, P < .001) irrespective of concurrent mitral regurgitation (r = .94, P < .001) and/or atrial fibrillation (r = .92, P < .001). By receiver operating characteristic (ROC) curves, MLSI2D  ≤ 8.6 mm showed 100% sensitivity and 76% specificity for very severe MS. MLSI2D  ≥ 11.2 mm determined progressive MS with 100% sensitivity and 82% specificity. The study population was then divided into a derivation group and a validation group. A regression equation for MVA by MLSI2D was derived in first group. Then, the MVA was calculated by this equation in validation group and was not significantly different from MVA3D .

CONCLUSION: MLSI2D showed an excellent ability to assess MS severity and correlates well with planimetered MVA measured by 3DTEE.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты