DOI 10.1002/ppul.26789

Медицинская библиотека · Pediatric pulmonology · 2024

Respiratory function testing for guiding ventilator mode conversion in congenital diaphragmatic hernia.

Kimura Sasagu, Toyoshima Katsuaki, Shimokaze Tomoyuki, Katsumata Kaoru, Saito Tomoko, Hoshino Rikuo

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

For patients with a congenital diaphragmatic hernia, conventional mechanical ventilation (CMV) and high-frequency oscillatory ventilation (HFOV) are used in initial ventilatory management. HFOV has recently been recommended as a rescue therapy; however, we use HFOV for initial ventilation management, with a preoperative challenge test for CMV conversion and respiratory function testing at the time of CMV conversion. We aimed to compare patient characteristics between CMV conversion- and HFOV-preferred treatment groups.

METHODS

Ventilator settings and blood gases were retrospectively evaluated pre- and post-CMV conversion, and respiratory function tests for compliance of the respiratory system (Crs) and for resistance of the respiratory system (Rrs) were performed during the trial to CMV conversion.

RESULTS

No differences were observed between the CMV conversion- and HFOV-preferred groups regarding gestational age, birth weight, and observed/expected lung area-to-head circumference ratios. The median Crs (ml/cmH2 O/kg) and Rrs (cmH2 O・kg/L/s) in the CMV conversion- and HFOV-preferred groups was 0.42 versus 0.53 (p = .44) and 467 versus 327 (p = .045), respectively. The pre and posttrial amount of change in blood gas levels and ventilator parameters in the CMV conversion- and HFOV-preferred groups were as follows: mean airway pressure, -2.0 versus 0 cmH2 O; partial pressure of carbon dioxide, 6.1 versus 2.9 Torr; alveolar-arterial oxygen difference, -39.5 versus -50 Torr; and oxygenation index, -1.0 versus -0.6; respectively.

CONCLUSION

Respiratory function tests were useful in tailoring ventilator settings. Patients with high Rrs values responded better to CMV conversion.

Для цитирования: Kimura Sasagu, Toyoshima Katsuaki, Shimokaze Tomoyuki, Katsumata Kaoru, Saito Tomoko, Hoshino Rikuo. Respiratory function testing for guiding ventilator mode conversion in congenital diaphragmatic hernia.. Pediatric pulmonology. 2024. DOI: 10.1002/ppul.26789.