m+Medelevator.RU
← Поиск публикаций
Circulation journal : official journal of the Japanese Circulation Society · 2024

Impact of 12-Month Angioscopic Thrombi and Yellow Plaque After Drug-Eluting Stent Implantation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nishino Masami, Egami Yasuyuki, Nohara Hiroaki, Kawanami Shodai, Ukita Kohei, Kawamura Akito, Yasumoto Koji, Okamoto Naotaka, Matsunaga-Lee Yasuharu, Yano Masamichi, Shiraki Tatsuya, Nakamura Daisuke, Mizote Isamu, Ishihara Takayuki, Mano Toshiaki, Ueno Takafumi, Nakatani Daisaku, Hikoso Shungo, Nanto Shinsuke, Sakata Yasushi, COLLABORATION Investigators

Аннотация

BACKGROUND: Coronary angioscopy (CAS) has 2 unique abilities: direct visualization of thrombi and plaque color. However, in the recent drug-eluting stent (DES) era, serial CAS findings after DES implantation have not been fully elucidated. We investigated the impact of CAS findings after implantation of a polymer-free biolimus A9-coated stent (PF-BCS) or durable polymer everolimus-eluting stent (DP-EES).

METHODS AND RESULTS: We investigated serial CAS and optical coherence tomography (OCT) findings at 1 and 12 months in 99 patients who underwent PF-BCS or DP-EES implantation. We evaluated factors correlated with angioscopic thrombi and yellow plaque, and the clinical impact of both thrombi and yellow plaque at 12 months (BTY). The BTY group included 17 (22%) patients. The incidence and grade of thrombi and yellow plaque decreased from 1 to 12 months. Although no patients had newly appearing thrombi at 12 months, 2 DP-EES patients had newly appearing yellow plaque at 12 months. Multivariable analysis revealed HbA1c, minimum stent area, and adequate strut coverage were significant factors correlated with 12-month angioscopic thrombi, and DP-EESs were significantly correlated with 12-month yellow plaque. However, BTY was not correlated with clinical events.

CONCLUSIONS: The management of diabetes, stent area, and adequate stent coverage are important for intrastent thrombogenicity and polymer-free stents are useful for stabilizing plaque vulnerability.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты