Heart rhythm · 2015

Incidence and characteristics of complications in the setting of second-generation cryoballoon ablation: A large single-center study of 500 consecutive patients.

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mugnai Giacomo, de Asmundis Carlo, Ciconte Giuseppe, Irfan Ghazala, Saitoh Yukio, Velagic Vedran, Ströker Erwin, Wauters Kristel, Hünük Burak, Brugada Pedro, Chierchia Gian-Battista

Аннотация

BACKGROUND: The second-generation cryoballoon Advance (CB-A) recently launched on the market has technical modifications designed to significantly improve procedural outcome with respect to the first-generation device.

OBJECTIVE: The purpose of this study was to evaluate the overall incidence of complications in a large sample of patients having undergone pulmonary vein (PV) isolation with CB-A technology.

METHODS: All consecutive patients who underwent PV isolation procedures using CB-A technology between June 2012 and February 2015 were considered. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease, left atrial diameter ≥55 mm, and contraindications to general anesthesia.

RESULTS: During the study period, 500 consecutive patients (67% male, age 57.6 ± 12.9 years) were enrolled. Major complications occurred in 10 patients (2.0%): vascular complications at the puncture site in 6 (1.2%), and thromboembolic events, cardiac tamponade, persisting phrenic nerve palsy, and retroperitoneal hematoma all occurred in a single patient respectively (0.2%). Phrenic nerve palsy occurred in 36 patients (7.2%) and did not revert in only 1 patient at final follow-up of 20 months. No deaths related to the procedure occurred. No predictors of major complication were found.

CONCLUSION: The present findings highlight that PV isolation using CB-A technology can be safely performed with a low incidence of adverse events. The incidence of major complications after atrial fibrillation ablation procedures using CB-A technology was 2% in our study. The most frequent complication consisted of vascular complications at the puncture site. No deaths related to the procedure occurred.