m+Medelevator.RU
← Поиск публикаций
Cardiovascular diabetology · 2023

Effects of exenatide on coronary stent's endothelialization in subjects with type 2 diabetes: a randomized controlled trial. The Rebuild study.

Рандомизированное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Santos-Pardo Irene, Witt Nils, Angerås Oskar, Nyström Thomas

Аннотация

BACKGROUND: Subjects with type 2 diabetes (T2D) have a higher risk of in-stent restenosis and stent thrombosis. The activation of the glucagon-like peptide-1 receptor (GLP-1R) has been suggested to induce several effects on the vasculature that may reduce the risk of stent failure following an angioplasty. The aim of this study is to evaluate the effect of the GLP-1R agonist exenatide on endothelialization of a modern drug-eluting stent (DES) in subjects with T2D.

METHODS: 38 subjects with T2D who were eligible for revascularization with implantation of DES were randomized to treatment with exenatide (once weekly) plus standard treatment, or to standard treatment alone. After 12 weeks, a new coronary angiography was performed to evaluate the percentage of strut coverage (primary endpoint) and the presence of neo-atherosclerosis by optical coherence tomography. This study was approved by the Stockholm's Ethical Review Board.

RESULTS: The two groups were well balanced regarding baseline clinical characteristics. Strut coverage was 95% (88.7-98.5%) in the exenatide group and 91.4% (88.8-98.5%) in the control group (p = 0.692). There were no significant differences between groups neither in the thickness of neo-intima (0.2 mm in both groups, p = 0.471), nor the maximal in-stent obstruction by neo-intima (15.5% in exenatide group vs 14.7% in control group, p = 0.801). No significant differences were detected in the rate of target lesion revascularization between groups (p = 0.224).

CONCLUSION: Twelve weeks treatment with exenatide did not lead to a significantly better stent coverage in people with T2D. No significant differences in the occurrence of neo-atherosclerosis were detected between groups.

TRIAL REGISTRATION: The study was registered at www.

CLINICALTRIALS: gov (Rebuild Study, NCT02621489).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты