Rapid detection of extended-spectrum β-Lactamases producers in Enterobacteriaceae using a calorimetry approach.

Lei J-E, Wang Q, Lin Y, Li F, Ma C, He Y, Xu J-R

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To design and assess a novel protocol that employs isothermal titration calorimetry (ITC) for rapid detection of extended-spectrum β-lactamase (ESBL)-producers in clinical pathogens.

METHODS AND

RESULTS

A total of 69 clinical Enterobacteriaceae isolates were examined in the new ESBL-ITC test by examining the heat profiles associated with enzyme hydrolysis of different substrates (imipenem, cefotaxime and clavulanic acid). The presence of β-lactamase genes in the bacteria tested was confirmed by PCR and DNA sequencing. Comparative analysis between ESBL-ITC and conventional minimum inhibitory concentrations (MIC)/combined disk method (CDM) showed high agreement between the two assays. However, the ESBL-ITC test had a remarkable advantage of providing testing result within 1 h, in comparison to the 32-48 h required by MIC/CDM.

CONCLUSIONS

The ESBL-ITC test developed in this work offers a new option for rapid and accurate detection of ESBL-producers.

SIGNIFICANCE AND IMPACT OF THE STUDY: Timely detection of ESBL-producers is vital to guide the decision-making process in clinical treatment as well as in hospital-infection control. The new ESBL-ITC test provides a rapid phenotypic assay that can be further adapted for clinical diagnosis of ESBL-producing pathogens.

Для цитирования: Lei J-E, Wang Q, Lin Y, Li F, Ma C, He Y, Xu J-R. Rapid detection of extended-spectrum β-Lactamases producers in Enterobacteriaceae using a calorimetry approach.. Journal of applied microbiology. 2020. DOI: 10.1111/jam.14841.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.