AIMS: Infections of cardiac implantable electronic devices (CIEDs) are infrequent but carry significant morbidity and mortality. We aimed to assess risk factors for 1-year mortality among patients with CIED infection and to evaluate if the type of infection and the presence of vegetation affect survival.

METHODS AND

RESULTS

We reviewed records of all patients with infected CIEDs who underwent transvenous lead extraction at our tertiary care centre between 2002 and 2008. Patients who presented with infection involving the device pocket were classified as 'pocket infection', and those who presented with bacteraemia with or without vegetation and a pocket that looked benign were classified as 'endovascular infection' (EVI). One-year mortality was examined using the social security death index. Five hundred and two patients were identified (68.5 ± 15 years); 289 (58%) had pocket infection and 213 (42%) had EVI. One-year mortality rate was 20%. Using multivariable Cox regression model, EVI was associated with significantly higher 1-year mortality (hazard ratio 2.1, P-value 0.0008). Among patients with EVI, 100 patients had vegetation on transoesophageal echo; however, there was no difference in 1-year mortality between patients with EVI and vegetation compared with patients with EVI and no vegetation (27, 27 vs. 40, 35%; P-value 0.188). Risk factors for 1-year mortality among patients with EVI included renal failure, worse functional class, and bleeding requiring transfusion. The presence of vegetation was not associated with increased 1-year mortality.

CONCLUSION

One-year mortality is higher among patients with EVI compared with patients with pocket infection; this increased mortality does not seem to be related to the presence of vegetations.

Для цитирования: Tarakji Khaldoun G, Wazni Oussama M, Harb Serge, Hsu Amy, Saliba Walid, Wilkoff Bruce L. Risk factors for 1-year mortality among patients with cardiac implantable electronic device infection undergoing transvenous lead extraction: the impact of the infection type and the presence of vegetation on survival.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2014. DOI: 10.1093/europace/euu147.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.