Journal of the American College of Cardiology · 2014

Clinical classifications of atrial fibrillation poorly reflect its temporal persistence: insights from 1,195 patients continuously monitored with implantable devices.

Клиническое исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Charitos Efstratios I, Pürerfellner Helmut, Glotzer Taya V, Ziegler Paul D

Аннотация

OBJECTIVES: This study aimed to identify how accurately the current clinical atrial fibrillation (AF) classifications reflect its temporal persistence.

BACKGROUND: Clinical classification of AF is employed to communicate its persistence, to select appropriate therapies, and as inclusion criterion for clinical trials.

METHODS: Cardiac rhythm histories of 1,195 patients (age 73.0 ± 10.1 years, follow-up: 349 ± 40 days) with implantable devices were reconstructed and analyzed. Patients were classified as having paroxysmal or persistent AF by physicians at baseline in accordance with current guidelines. AF burden, measured as the proportion of time spent in AF, was obtained from the device. Additionally we evaluated the agreement between clinical and device-derived AF classifications.

RESULTS: Patients within the same clinical class were highly heterogeneous with regards to AF temporal persistence. Agreement between the clinical AF classification and the objective device-derived assessments of AF temporal persistence was poor (Cohen's kappa: 0.12 [95% CI: 0.05 to 0.18]). Patient characteristics influenced the clinical decision to classify AF as paroxysmal or persistent. Higher ejection fraction (odds ratio: 0.97/per unit [95% CI: 0.95 to 0.98/per unit]; p < 0.0001) and presence of coronary artery disease (odds ratio: 0.53 [95% CI: 0.32 to 0.88]; p = 0.01) were independently associated with a lower probability of being classified as persistent AF for the same AF burden level.

CONCLUSIONS: The currently used clinical AF classifications poorly reflect AF temporal persistence. Patient characteristics significantly influence the physician's classification of AF. Patients classified in identical clinical categories may be inherently heterogeneous with regard to AF temporal persistence. Further study is required to determine if patient selection on the basis of objective criteria derived from rigorous AF monitoring can improve reported outcomes and better identify responders and non-responders to treatments. (OMNI Study-Assessing Therapies in Medtronic Pacemaker, Defibrillator, and Cardiac Resynchronization Therapy Devices; NCT00277524; TRENDS: A Prospective Study of the Clinical Significance of Atrial Arrhythmias Detected by Implanted Device Diagnostics; NCT00279981).