MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2014.04.069

Медицинская библиотека · International journal of cardiology · 2014

Impact of combined supine and prone myocardial perfusion imaging using an ultrafast cardiac gamma camera for detection of inferolateral coronary artery disease.

Goto Kenji, Takebayashi Hideo, Kihara Yasuki, Yamane Hiroki, Hagikura Arata, Morimoto Yoshimasa, Kikuta Yuetsu, Sato Katsumasa, Taniguchi Masahito, Hiramatsu Shigeki, Haruta Seiichi

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Although combined supine and prone acquisitions improve the detection of inferolateral obstructive coronary artery disease (CAD), the predictors of inaccurate detection of inferolateral ischemia have not been reported by using cadmium zinc telluride (CZT) myocardial perfusion imaging (MPI).

METHODS AND

RESULTS

Vasodilator stress (99m)Tc tetrofosmin MPI using CZT camera and coronary angiography was performed in 322 patients within an interval of 2 months. Prone MPI was performed immediately after supine MPI. Narrowing of the luminal diameter ≥ 75% was considered significant. The presence of an abnormality on both supine and prone images was considered significant. Combined supine and prone imaging, compared with supine-only quantification, was more specific (93% vs. 72%, respectively, p<0.0001) and accurate (88% vs. 74%, p<0.0001) without compromising sensitivity (82% vs. 68%, p=0.10). The area under the curve for detecting inferolateral ischemia was 0.769 (95% CI 0.705-0.833) for supine imaging and 0.802 (95% CI 0.730-0.875) for combined supine and prone imaging (p<0.05). Multivariable analysis revealed that previous inferolateral myocardial infarction was an independent predictor of a false diagnosis (odds ratio=3.45, 95% confidence interval [CI] 1.62-7.37, p<0.001).

CONCLUSIONS

Combined supine and prone quantitative CZT MPI enhances the detection of inferolateral CAD without adversely affecting its sensitivity. However, we recommend inferolateral ischemia be monitored in patients with a history of previous inferolateral MI because previous inferolateral MI is a predictor of inaccurate diagnosis.

Для цитирования: Goto Kenji, Takebayashi Hideo, Kihara Yasuki, Yamane Hiroki, Hagikura Arata, Morimoto Yoshimasa, Kikuta Yuetsu, Sato Katsumasa, Taniguchi Masahito, Hiramatsu Shigeki, Haruta Seiichi. Impact of combined supine and prone myocardial perfusion imaging using an ultrafast cardiac gamma camera for detection of inferolateral coronary artery disease.. International journal of cardiology. 2014. DOI: 10.1016/j.ijcard.2014.04.069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.