Journal of the American College of Cardiology · 2013
Percutaneous left atrial appendage closure with the AMPLATZER cardiac plug device in patients with nonvalvular atrial fibrillation and contraindications to anticoagulation therapy.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Urena Marina, Rodés-Cabau Josep, Freixa Xavier, Saw Jacqueline, Webb John G, Freeman Mélanie, Horlick Eric, Osten Mark, Chan Albert, Marquis Jean-Francois, Champagne Jean, Ibrahim Réda
Аннотация
OBJECTIVES: The aim of this study was to evaluate the results associated with left atrial appendage closure (LAAC) with the AMPLATZER Cardiac Plug (ACP) (St. Jude Medical, Minneapolis, Minnesota) in patients with nonvalvular atrial fibrillation and absolute contraindications to anticoagulation therapy.
BACKGROUND: Few data exist on the late outcomes after LAAC in patients with absolute contraindications to warfarin.
METHODS: A total of 52 patients with nonvalvular atrial fibrillation underwent LAAC with the ACP device in 7 Canadian centers. Most patients received short-term (1 to 3 months) dual-antiplatelet therapy after the procedure and single-antiplatelet therapy thereafter. A transesophageal echocardiography was performed in 74% of patients at the 6-month follow-up. No patient was lost to follow-up (≥ 12 months in all patients).
RESULTS: The mean age and median (interquartile range) CHADS2 score were 74 ± 8 years and 3 (2 to 4), respectively. The procedure was successful in 98.1% of the patients, and the main complications were device embolization (1.9%) and pericardial effusion (1.9%), with no cases of periprocedural stroke. At a mean follow-up of 20 ± 5 months, the rates of death, stroke, systemic embolism, pericardial effusion, and major bleeding were 5.8%, 1.9%, 0%, 1.9%, and 1.9%, respectively. The presence of mild peridevice leak was observed in 16.2% of patients at the 6-month follow-up as evaluated by transesophageal echocardiography. There were no cases of device thrombosis.
CONCLUSIONS: In patients with nonvalvular atrial fibrillation at high risk of cardioembolic events and absolute contraindications to anticoagulation, LAAC using the ACP device followed by dual-/single-antiplatelet therapy was associated with a low rate of embolic and bleeding events after a mean follow-up of 20 months. No cases of severe residual leak or device thrombosis were observed at the 6-month follow-up.
BACKGROUND: Few data exist on the late outcomes after LAAC in patients with absolute contraindications to warfarin.
METHODS: A total of 52 patients with nonvalvular atrial fibrillation underwent LAAC with the ACP device in 7 Canadian centers. Most patients received short-term (1 to 3 months) dual-antiplatelet therapy after the procedure and single-antiplatelet therapy thereafter. A transesophageal echocardiography was performed in 74% of patients at the 6-month follow-up. No patient was lost to follow-up (≥ 12 months in all patients).
RESULTS: The mean age and median (interquartile range) CHADS2 score were 74 ± 8 years and 3 (2 to 4), respectively. The procedure was successful in 98.1% of the patients, and the main complications were device embolization (1.9%) and pericardial effusion (1.9%), with no cases of periprocedural stroke. At a mean follow-up of 20 ± 5 months, the rates of death, stroke, systemic embolism, pericardial effusion, and major bleeding were 5.8%, 1.9%, 0%, 1.9%, and 1.9%, respectively. The presence of mild peridevice leak was observed in 16.2% of patients at the 6-month follow-up as evaluated by transesophageal echocardiography. There were no cases of device thrombosis.
CONCLUSIONS: In patients with nonvalvular atrial fibrillation at high risk of cardioembolic events and absolute contraindications to anticoagulation, LAAC using the ACP device followed by dual-/single-antiplatelet therapy was associated with a low rate of embolic and bleeding events after a mean follow-up of 20 months. No cases of severe residual leak or device thrombosis were observed at the 6-month follow-up.