MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · AJNR. American journal of neuroradiology · 2007

Dynamic 3D-CT angiography.

Matsumoto M, Kodama N, Endo Y, Sakuma J, Suzuki Ky, Sasaki T, Murakami K, Suzuki Ke, Katakura T, Shishido F

Клинический случайОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: 3D-CT angiography (3D-CTA), a vessel-cast technique, is useful in the diagnosis of patients with brain lesions and cerebrovascular disease. However, it provides no information on blood-flow dynamics. Therefore, we developed a new technique, dynamic 3D-CTA (d3D-CTA), that yields 3D images of the vasculature and allows assessment of the hemodynamics and of the cerebral perfusion.

METHODS

We subjected 12 patients to d3D-CTA; 7 had brain tumors, 4 had arteriovenous malformations (AVMs), and 1 presented with cervical internal carotid artery occlusion. d3D-CTA was performed with a multidetector-row CT scanner with 64 detectors; the parameters were 0.5-mm section thickness, 0.5 seconds per rotation, 135 kV, and 150 mA. Contrast medium (total volume, 30-35 mL) was injected at 6-7 mL/s; scanning was started after a 5-second delay. Scans were generated with volume-rendering reconstruction and displayed in cine mode.

RESULTS

We succeeded in obtaining d3D-CTA scans in all cases. The scans yielded 3D information on the vascular structures and hemodynamics and on the status of the cerebral perfusion.

CONCLUSION

d3D-CTA facilitates the acquisition of information on the vascular and cerebral dynamic blood flow on 3D-CTA images. Despite the relatively high radiation exposure and contrast injection speed and its limited scan range, this technique is useful for the diagnosis of patients with brain tumors or cerebrovascular disease and for treatment planning.

Другие публикации по теме

Carotid StenosisCerebral AngiographyCerebrovascular CirculationImaging, Three-Dimensional
Для цитирования: Matsumoto M, Kodama N, Endo Y, Sakuma J, Suzuki Ky, Sasaki T, Murakami K, Suzuki Ke, Katakura T, Shishido F. Dynamic 3D-CT angiography.. AJNR. American journal of neuroradiology. 2007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.