Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2007
Dual cerebral protection technique during carotid stenting.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Milosevic Zoran V, Kocijancic Igor J, Bunc Matjaz, Bajrović Fajko F, Zvan Bojana
Аннотация
PURPOSE: To present a technique for internal carotid artery stenting (CAS) with dual cerebral protection in patients with high-grade stenosis caused by large, soft atherosclerotic plaques.
TECHNIQUE: The MO.MA proximal cerebral protection device is first placed in the external and common carotid arteries. Complete blockade of blood flow is achieved by inflating the occlusion balloons. A Spider filter is delivered to the distal internal carotid artery. All procedural steps of CAS are performed during continuous and simultaneous proximal occlusion and distal filter protection. After postdilation of the stent, the occlusion balloons are deflated, and antegrade flow is re-established with the distal filter basket still open.
CONCLUSION: In selected patients with large atherosclerotic plaques, a dual cerebral protection technique during CAS may be a more efficacious form of cerebral protection than a single protection device.
TECHNIQUE: The MO.MA proximal cerebral protection device is first placed in the external and common carotid arteries. Complete blockade of blood flow is achieved by inflating the occlusion balloons. A Spider filter is delivered to the distal internal carotid artery. All procedural steps of CAS are performed during continuous and simultaneous proximal occlusion and distal filter protection. After postdilation of the stent, the occlusion balloons are deflated, and antegrade flow is re-established with the distal filter basket still open.
CONCLUSION: In selected patients with large atherosclerotic plaques, a dual cerebral protection technique during CAS may be a more efficacious form of cerebral protection than a single protection device.
Предметные рубрики MeSH
AgedAngioplasty, BalloonBalloon OcclusionCarotid Artery DiseasesCarotid Artery, CommonCarotid Artery, ExternalCarotid Artery, InternalCarotid StenosisCerebrovascular DisordersEquipment DesignFiltrationHumansIntracranial EmbolismMaleMiddle AgedRadiography, InterventionalRegional Blood FlowSeverity of Illness IndexStentsUltrasonography, Doppler, Duplex