Impact of cerebral protection devices on early outcome of carotid stenting.

Castriota Fausto, Cremonesi Alberto, Manetti Raffaella, Liso Armando, Oshola Kareem, Ricci Enrico, Balestra Guido

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the impact of cerebral protection devices on the procedural safety and outcome of carotid stent procedures.

METHODS

From June 1997 to July 2001, 275 consecutive patients (208 men; mean age 71 +/- 7.4 years) underwent percutaneous angioplasty and/or stenting of the extracranial carotid artery. In the first 125 (45.4%) patients, the procedures were performed without cerebral protection. After January 2000, protection devices were routinely used (150 [54.6%] patients), including the Angioguard filter, GuardWire occlusion system, TRAP Vascular Filtration System, EPI Filter Wire, NeuroShield, Parodi Anti-Embolism System, and Medicorp occlusive balloon.

RESULTS

The percutaneous procedures were effective in 273 (99.3%) patients. No death or major stroke occurred in either group. In the unprotected group, 5 (4.0%) complications occurred: 3 (2.4%) minor strokes, 1 (0.8%) transient ischemic attack (TIA), and 1 (0.8%) subarachnoid hemorrhage. In the patients treated under cerebral protection, there were 2 (1.3%) complications: 1 (0.7%) minor stroke and 1 (0.7%) subarachnoid hemorrhage. There were 4 (3.2%) periprocedural embolic complications in the unprotected group versus 1 (0.7%) in the protected patients.

CONCLUSIONS

Our data suggest that percutaneous dilation and stenting of the carotid arteries protected by cerebral protection devices is feasible and effective. In a consecutive series, the use of the cerebral protection systems reduced the acute neurological event rate related to embolic complications by 79%.

Для цитирования: Castriota Fausto, Cremonesi Alberto, Manetti Raffaella, Liso Armando, Oshola Kareem, Ricci Enrico, Balestra Guido. Impact of cerebral protection devices on early outcome of carotid stenting.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2002. DOI: 10.1177/152660280200900611.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.