m+Medelevator.RU
← Поиск публикаций
Journal of shoulder and elbow surgery · 2016

Radiographic evaluation of short-stem press-fit total shoulder arthroplasty: short-term follow-up.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Casagrande Danielle J, Parks Di L, Torngren Travis, Schrumpf Mark A, Harmsen Samuel M, Norris Tom R, Kelly James D

Аннотация

BACKGROUND: Humeral loosening is an uncommon etiology for revision shoulder arthroplasty. We aimed to evaluate the radiographic and clinical outcomes of a short-stem press-fit humeral component after primary total shoulder arthroplasty.

METHODS: We reviewed our patient database, from January 2008 to December 2011, for primary total shoulder arthroplasties performed with a short-stem press-fit humeral component. Radiographs and clinical outcomes were evaluated in the immediate postoperative period and at the most recent follow-up, with at least 24 months of data for all patients.

RESULTS: There were 73 shoulders that met our inclusion criteria, but 4 underwent revision before 2 years' follow-up. Only 1 of these 4 was revised for aseptic humeral loosening. Sixty-nine shoulders had at least 24 months of radiographic follow-up, and 62 had radiographic and clinical follow-up. Of the 69 shoulders, 5 underwent revision for humeral loosening: 1 for aseptic loosening and 4 for infection. Two other shoulders with humeral loosening were asymptomatic, and the patients refused revision surgery. The overall revision rate for humeral loosening was 8.2% (6 of 73 shoulders). Radiolucent zones of any size were seen in 71.0%, with 8.7% of these shoulders identified as having humeral stems at risk of future loosening. Significant improvements were made in most of the measured clinical outcomes.

CONCLUSIONS: A high percentage of radiolucency was seen around the short-stem press-fit humeral components evaluated in this study at short-term follow-up. The overall rates of loosening and revision for the humeral implant examined in this study are higher than those noted in other recent studies evaluating press-fit stems. The cause of radiolucency and humeral loosening for this implant is not fully understood.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты