m+Medelevator.RU
← Поиск публикаций
Journal of dentistry · 2023

An optical fiber-based point-of-care test for periodontal MMP-8 detection: A proof of concept.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Guida Luigi, Bencivenga Debora, Annunziata Marco, Arcadio Francesco, Borriello Adriana, Della Ragione Fulvio, Formisano Alessandro, Piccirillo Angelantonio, Zeni Luigi, Cennamo Nunzio

Аннотация

OBJECTIVES: The evaluation of salivary biomarkers has been proposed as a simple and non-invasive aid to the conventional periodontal diagnosis based on clinical-radiographic parameters. Matrix metalloproteinase-8 (MMP-8), especially in its active form, is considered one of the most reliable biomarkers of periodontitis, and point-of-care tests (POCTs) have been proposed for its clinical monitoring. In this proof-of-concept study, a novel highly sensitive POCT based on a plastic optical fiber (POF) biosensor exploiting surface plasmon resonance (SPR) to detect salivary MMP-8 is described.

METHODS: A SPR-POF biosensor was functionalized with a specific antibody to develop a surface-assembled monolayer (SAM) for the detection of total MMP-8. A white light source and a spectrometer connected to the biosensor were used to quantify MMP-8 level in both buffer and real matrix (saliva) by analysing the shift of the resonance wavelength determined by the specific antigen-antibody binding upon the SAM.

RESULTS: Dose-response curves by serial dilutions of human recombinant MMP-8 were realized, obtaining a limit of detection (LOD) of 40 pM (1.76 ng/ml) in buffer and 225 pM (9.9 ng/ml) in saliva and high selectivity compared to interferent analytes (MMP-2 and IL-6).

CONCLUSIONS: The proposed optical fiber-based POCT was able to detect and measure total MMP-8 with high selectivity and very low LOD in both buffer and saliva.

CLINICAL SIGNIFICANCE: The SPR-POF technology may be employed to create highly sensitive biosensors to monitor salivary MMP-8 levels. The possibility of specifically detecting its active, rather than total, form need to be further investigated. If confirmed and clinically validated, such a device may represent a promising tool to make an immediate, highly sensitive and reliable diagnosis of periodontitis, and to carry out a timely and targeted therapy, possibly helping to prevent the onset of local and systemic periodontitis-related complications.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты