MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of heart valve disease · 2003

Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.

Shi Yubing, Zhao Yong, Yeo Tony Joon Hock, Hwang Ned H C

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM OF THE STUDY: Most previous computational fluid dynamics (CFD) studies of blood flow in mechanical heart valves (MHVs) have not efficiently addressed the important features of moving leaflet and blood-leaflet interaction. Herein, computationally efficient approaches were developed to study these features and to obtain better insight into the pulsatile flow field in bileaflet MHVs.

METHODS

A simple and effective method to track the moving boundary was proposed, and an efficient method for calculating the blood-leaflet interaction applied. In this way, a CFD code was developed to study the pulsatile flow field around bileaflet MHVs. The CFD code was parallelized on a supercomputer to reduce turn-around time in the simulation. The solver was then used to study the opening process in a St. Jude Medical (SJM) size 29 bileaflet MHV.

RESULTS

CFD results showed that, in the opening process, the flow field was consistently partitioned into two side channels and a central channel due to the presence of the two leaflets. In the flow field near the surface of the two leaflets, the fluid velocity followed the local surface velocity of the leaflets, thus showing a strong blood-leaflet interaction effect. Throughout the valve-opening process, peak velocities were always observed near the tips of the valve leaflet. The CFD simulation showed that the opening process took approximately 0.044 s, which compared well with experimental findings.

CONCLUSION

The new computational approaches were efficient and able to address the moving leaflet and blood-leaflet interaction. The flow field in the opening process of a SJM 29 bileaflet MHV was successfully simulated using the developed solver.

Для цитирования: Shi Yubing, Zhao Yong, Yeo Tony Joon Hock, Hwang Ned H C. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.. The Journal of heart valve disease. 2003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.