Transcranial Doppler-detected microemboli in patients with acute stroke.
Аннотация
BACKGROUND AND PURPOSE: Transcranial Doppler sonography (TCD) has been used to detect microembolic signals in a variety of clinical situations. We studied the prevalence of TCD-detected microemboli in 38 acute stroke patients.
METHODS
Consecutive patients with acute anterior circulation stroke were stratified into high-risk (group 1), medium-risk (group 2), and low-risk (group 3) groups based on their risk factors for cerebral embolism.
RESULTS
Microemboli were detected in 11% of patients. They were present in 17% of group 1, 10% of group 2, and 0% of group 3 patients. Emboli were present in patients with mechanical prosthetic valves, carotid stenosis (> 70%), and mitral valve strands with a patent foramen ovale. Patients with microemboli more frequently had a history of cerebral ischemia compared with patients without microemboli (P < .05). They also more frequently had recent (< 3 months) symptoms compared with patients without microemboli (P < .05). In patients with a cardiac source of embolization, the number of microemboli detected was directly proportional to the acuity of previous symptoms.
CONCLUSIONS
These data suggest that TCD-detected microemboli are associated with an increased prevalence of prior cerebrovascular ischemia. The presence of TCD-detected microemboli could be a risk factor for cerebrovascular ischemia.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.