MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2023.10.140

Медицинская библиотека · World neurosurgery · 2023

Optic Canal Size is an Indicator for the Accessory Optic Canal: Applications for Anterior Clinoidectomy.

Zdilla Matthew J, Cusick Abbey M, Cowher Abigail E, Choi Janie S, Lambert H Wayne

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The ophthalmic artery normally travels with the optic nerve through the optic canal. However, sometimes, the ophthalmic artery travels through a foramen within the optic strut named an accessory optic canal, double optic canal, or ophthalmic canal. This variant puts individuals at an increased risk for blindness or death during anterior clinoidectomy due to unforeseen hemorrhage of the ophthalmic artery or internal carotid artery when the optic strut is separated from the body of the sphenoid bone. Several features make the accessory optic canal difficult to recognize on imaging: its variant nature, small size, and ability to masquerade as a caroticoclinoid foramen or a pneumatized sphenoidal structure. Hence, improved methods of presurgical identification are warranted. The aim of this study was to assess the size and shape of the optic canal, with and without a concomitant accessory optic canal, to determine whether measurement of the optic canal may provide useful information regarding the presence of an accessory optic canal.

METHODS

In 191 dry crania, optic canals with and without concomitant accessory optic canals were assessed for the following parameters: canal area, canal perimeter, circularity, solidity, the axes and aspect ratio of a best-fit ellipse, and roundness.

RESULTS

Normal optic canals were found to have a larger area (P = 0.036), perimeter (P = 0.043), and minor axis of a best-fit ellipse (P = 0.031) than the optic canals that occurred alongside accessory optic canals.

CONCLUSIONS

Asymmetry in optic canal size can help indicate the presence of a unilateral accessory optic canal before surgery.

Для цитирования: Zdilla Matthew J, Cusick Abbey M, Cowher Abigail E, Choi Janie S, Lambert H Wayne. Optic Canal Size is an Indicator for the Accessory Optic Canal: Applications for Anterior Clinoidectomy.. World neurosurgery. 2023. DOI: 10.1016/j.wneu.2023.10.140.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.