Ultrasonographic diaphragmatic excursion is inaccurate and not better than the MRC score for predicting weaning-failure in mechanically ventilated patients.

Carrie Cédric, Gisbert-Mora Chloé, Bonnardel Eline, Gauche Bernard, Biais Matthieu, Vargas Frédéric, Hilbert Gilles

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the ability of diaphragmatic ultrasound (US) to predict weaning failure in mechanically ventilated patients undergoing a first spontaneous breathing trial (SBT).

METHODS

During a 4-month period, 67 consecutive patients eligible for a first SBT underwent US measurements of maximal diaphragmatic excursion (MDE) by a right anterior subcostal approach. Weaning failure was defined as either the failure of SBT or the need for resumption of ventilatory support for acute respiratory failure or death within 48h following successful extubation. The accuracy of diaphragmatic ultrasound and the Medical Research Council (MRC) score when predicting weaning failure was assessed via a receiver operating curve analysis.

RESULTS

The feasibility rate for the ultrasound measurements was 63%. Mean values of MDE were significantly higher in patients who succeeded at their first weaning attempt (4.1±2.1 versus 3±1.8cm, P=0.04). Using a threshold of MDE≤2.7cm, the sensitivity and specificity of diaphragmatic ultrasound in predicting weaning failure were 59% [39-77%] and 71% [57-82%] with an AUC at 0.65 [0.51-0.78]. There was no significant difference between MDE values and MRC scores for predicting weaning failure (P=0.73).

CONCLUSION

A decrease in MDE values may be associated with an unfavourable weaning outcome. Diaphragmatic excursion measured by ultrasound is however unable by itself to predict weaning failure at the bedside of patients undergoing a first spontaneous breathing trial and does not provide any additional value compared to the MRC score.

Для цитирования: Carrie Cédric, Gisbert-Mora Chloé, Bonnardel Eline, Gauche Bernard, Biais Matthieu, Vargas Frédéric, Hilbert Gilles. Ultrasonographic diaphragmatic excursion is inaccurate and not better than the MRC score for predicting weaning-failure in mechanically ventilated patients.. Anaesthesia, critical care & pain medicine. 2016. DOI: 10.1016/j.accpm.2016.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.