Journal of critical care · 2016
Predicting success of high-flow nasal cannula in pneumonia patients with hypoxemic respiratory failure: The utility of the ROX index.
СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Roca Oriol, Messika Jonathan, Caralt Berta, García-de-Acilu Marina, Sztrymf Benjamin, Ricard Jean-Damien, Masclans Joan R
Аннотация
PURPOSE: The purpose of the study is to describe early predictors and to develop a prediction tool that accurately identifies the need for mechanical ventilation (MV) in pneumonia patients with hypoxemic acute respiratory failure (ARF) treated with high-flow nasal cannula (HFNC).
MATERIALS AND METHODS: This is a 4-year prospective observational 2-center cohort study including patients with severe pneumonia treated with HFNC. High-flow nasal cannula failure was defined as need for MV. ROX index was defined as the ratio of pulse oximetry/fraction of inspired oxygen to respiratory rate.
RESULTS: One hundred fifty-seven patients were included, of whom 44 (28.0%) eventually required MV (HFNC failure). After 12 hours of HFNC treatment, the ROX index demonstrated the best prediction accuracy (area under the receiver operating characteristic curve 0.74 [95% confidence interval, 0.64-0.84]; P<.002). The best cutoff point for the ROX index was estimated to be 4.88. In the Cox proportional hazards model, a ROX index greater than or equal to 4.88 measured after 12 hours of HFNC was significantly associated with a lower risk for MV (hazard ratio, 0.273 [95% confidence interval, 0.121-0.618]; P=.002), even after adjusting for potential confounding.
CONCLUSIONS: In patients with ARF and pneumonia, the ROX index can identify patients at low risk for HFNC failure in whom therapy can be continued after 12 hours.
MATERIALS AND METHODS: This is a 4-year prospective observational 2-center cohort study including patients with severe pneumonia treated with HFNC. High-flow nasal cannula failure was defined as need for MV. ROX index was defined as the ratio of pulse oximetry/fraction of inspired oxygen to respiratory rate.
RESULTS: One hundred fifty-seven patients were included, of whom 44 (28.0%) eventually required MV (HFNC failure). After 12 hours of HFNC treatment, the ROX index demonstrated the best prediction accuracy (area under the receiver operating characteristic curve 0.74 [95% confidence interval, 0.64-0.84]; P<.002). The best cutoff point for the ROX index was estimated to be 4.88. In the Cox proportional hazards model, a ROX index greater than or equal to 4.88 measured after 12 hours of HFNC was significantly associated with a lower risk for MV (hazard ratio, 0.273 [95% confidence interval, 0.121-0.618]; P=.002), even after adjusting for potential confounding.
CONCLUSIONS: In patients with ARF and pneumonia, the ROX index can identify patients at low risk for HFNC failure in whom therapy can be continued after 12 hours.