MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-023-05028-9

Медицинская библиотека · Clinical oral investigations · 2023

Comparison of the performance of various virtual articulator mounting procedures: a self-controlled clinical study.

Lin Honglei, Pan Yu, Wei Xia, Wang Yinghui, Yu Hao, Cheng Hui

Контролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This clinical study aimed to compare the performance of various virtual articulator (VA) mounting procedures in the participants' natural head position (NHP).

MATERIALS AND

METHODS

Fourteen participants with acceptable dentitions and jaw relationships were recruited in this study registered in the Clinical Trials Registry (#NCT05512455; August 2022). A virtual facebow was designed for virtual mounting and hinge axis measurement. Intraoral scans were obtained, and landmarks were placed on each participant's face to register the horizontal plane in NHP. Six virtual mounting procedures were performed for each participant. The average facebow group (AFG) used an indirect digital procedure by using the average facebow record. The average mounting group (AMG) aligned virtual arch models to VA's average occlusal plane. The smartphone facial scan group (SFG) and professional facial scan group (PFG) used facial scan images with Beyron points and horizontal landmarks, respectively. The cone-beam computed tomography (CBCT) scan group (CTG) used the condyle medial pole, and horizontal landmarks were applied. The kinematic facebow group (KFG) served as the control group, and a direct digital procedure was applied using a kinematic digital facebow and the 3D skull model. Deviations of the reference plane and the hinge axis between the KFG and other groups were calculated. The inter-observer variability in virtual mounting software operation was then evaluated using the interclass correlation coefficient (ICC) test.

RESULTS

In virtual condylar center deviations, the CTG had the lowest condylar deviations. The AFG showed larger condylar deviations than PFG, SFG, and CTG. There was no statistically significant difference between the AFG and the AMG and between the PFG and the SFG. In reference plane deviations, the AMG showed the largest angular deviation (8.23 ± 3.29°), and the AFG was 3.89 ± 2.25°. The angular deviations of PFG, SFG, and CTG were very small (means of each group < 1.00°), and there was no significant difference among them. There was no significant difference between the researchers, and the ICC test showed moderate to excellent reliability for the virtual condylar center and good to excellent reliability for the reference plane in the operation of the virtual mounting software.

CONCLUSIONS

CBCT scan provided the lowest hinge axis deviation in virtual mounting compared to average mounting, facebow record, and facial scans. The performance of the smartphone facial scanner in virtual mounting was similar to that of the professional facial scanner. Direct virtual mounting procedures using horizontal landmarks in NHP accurately recorded the horizontal plane.

CLINICAL RELEVANCE: Direct digital procedures can be reliably used for virtual articulator mounting. The use of a smartphone facial scanner provides a suitable and radiation-free option for clinicians.

Для цитирования: Lin Honglei, Pan Yu, Wei Xia, Wang Yinghui, Yu Hao, Cheng Hui. Comparison of the performance of various virtual articulator mounting procedures: a self-controlled clinical study.. Clinical oral investigations. 2023. DOI: 10.1007/s00784-023-05028-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.