m+Medelevator.RU
← Поиск публикаций
Annals of clinical biochemistry · 2003

A novel method for measuring serum ornithine carbamoyltransferase.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ishikawa Hiroaki, Matsuzawa Takeo, Ohashi Koji, Nagamura Yoichi

Аннотация

BACKGROUND: Serum ornithine carbamoyltransferase is a diagnostic marker of hepatic disorders due to its localization in periportal mitochondria.

METHODS: We have developed a new method for the determination of serum ornithine carbamoyltransferase. It is based on the reverse reaction of ornithine carbamoyltransferase, using ornithine-ketoacid aminotransferase, Delta(1)-pyrroline-5-carboxylate dehydrogenase and glutamate dehydrogenase, which together convert citrulline through ornithine to glutamate. The glutamate is then quantitatively measured using glutamate oxidase and Trinder's reagent.

RESULTS: The results obtained by this method agreed well with those obtained using the diacetylmonoxime method as a gold standard [correlation coefficient (r) = 0.973 P<0.001]. The endogenous amino acids sensitive to this method in serum (glutamate, ornithine and Delta(1)-pyrroline-5-carboxylate) were eliminated by the initial futile reaction. The new method appears to be more accurate at low levels of ornithine carbamoyltransferase activity than the diacetylmonoxime method.

CONCLUSIONS: Here we report a new method for serum ornithine carbamoyl-transferase assay which might be useful for clinical diagnosis of hepatic disorders, including hepatic cancer.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты