Tomographically normal partner eye in very asymmetrical corneal ectasia: biomechanical analysis.
Аннотация
PURPOSE: To point out the biomechanical changes of the topographically and tomographically normal partner eye (NPE) in patients with very asymmetrical corneal ectasia.
SETTING
Department of Ophthalmology, Saarland University Medical Center in Homburg/Saar, Germany.
DESIGN
Retrospective study.
METHODS
The topographical and tomographical results of the NPE were assessed using the Pentacam HR and the biomechanical corneal properties using the Ocular Response Analyzer (keratoconus match index [KMI], corneal hysteresis [CH], and corneal resistance factor [CRF]) and the Corvis ST (topographic biomechanical index [TBI] and Corvis biomechanical index) and compared those results with a normal control group (CG).
RESULTS
The clinical records of 26 patients recruited from the Homburg Keratoconus Center diagnosed with a very asymmetrical corneal ectasia were reviewed. The NPE (8.5 ± 1.5 mm Hg) showed a significantly more pathological CH (P < .001) compared with the CG. The CRF was also significantly more pathological (P = .04) for the NPE (8.3 ± 1.5 mm Hg) compared with the CG. The NPE (0.62 ± 0.32) showed a nonsignificant (P = .08) more pathological KMI compared with the CG. Nineteen (73.1%) of 26 NPE had a KMI less than 0.72 and were considered pathological. Compared with the CG, the TBI of the NPE (0.19 ± 0.25) did not differ significantly overall (P = .57). However, 5 (19.2%) of 26 eyes had a TBI more than 0.29 and were considered pathological.
CONCLUSIONS
Topographically and tomographically NPEs in very asymmetrical corneal ectasia frequently showed biomechanical changes. This should be considered before planning any type of refractive corneal surgery in such patients.