m+Medelevator.RU
← Поиск публикаций
Translational vision science & technology · 2020

Detecting Mechanical Anisotropy of the Cornea Using Brillouin Microscopy.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Webb Joshua N, Zhang Hongyuan, Sinha Roy Abhijit, Randleman James Bradley, Scarcelli Giuliano

Аннотация

PURPOSE: The purpose of this study was to detect the mechanical anisotropy of the cornea using Brillouin microscopy along different perturbation directions.

METHODS: Brillouin frequency shift of both whole globes (n = 10) and cornea punches (n = 10) were measured at different angles to the incident laser, thereby probing corneal longitudinal modulus of elasticity along different directions. Frequency shift of virgin (n = 26) versus cross-linked corneas (n = 15) over a large range of hydration conditions were compared in order to differentiate the contributions to Brillouin shift due to hydration from those due to stromal tissue.

RESULTS: We detected mechanical anisotropy of corneas, with an average frequency shift increase of 53 MHz and 96 MHz when the instrument probed from 0° to 15° and 30° along the direction of the stromal fibers. Brillouin microscopy did not lose sensitivity to mechanical anisotropy up to 96% water content. We experimentally measured and theoretically modeled how mechanical changes independent of hydration affect frequency shift as a result of corneal cross-linking by isolating an approximately 100 MHz increase in frequency shift following a cross-linking procedure purely due to changes of stromal tissue mechanics.

CONCLUSIONS: Brillouin microscopy is sensitive to mechanical anisotropy of the stroma even in highly hydrated corneas. The agreement between model and experimental data suggested a quantitative relationship between Brillouin frequency shift, hydration state of the cornea, and stromal tissue stiffness.

TRANSLATIONAL RELEVANCE: The protocol and model validated throughout this study offer a path for comprehensive measurements of corneal mechanics within the clinic; allowing for improved evaluation of the long-term mechanical efficacy of cross-linking procedures.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты