MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1120672120945662

Медицинская библиотека · European journal of ophthalmology · 2020

Evolution of corneal flattening after repeated corneal cross-linking during a 6-year follow-up.

Grentzelos Michael A, Voulgari Nafsika, Giacuzzo Clarice, Droutsas Konstantinos, Kymionis George D

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report the evolution of corneal flattening after repeated corneal cross-linking (CXL) in a patient with progressive keratoconus during a 6-year follow-up.

METHODS

Case report.

RESULTS

A 27-year-old female underwent CXL for progressive keratoconus. Postoperatively, corneal topography revealed keratoconus progression with an increase of 1.20 diopters (D) in maximum keratometry (Kmax) and CXL was repeated. After the second treatment, a continuing significant corneal flattening (up to 16.00 D in Kmax) was observed during the first 5 years followed by stabilization during the last sixth year of follow-up. Both uncorrected and corrected distance visual acuity were improved while corneal thickness was decreased. There were no complications such as corneal opacification or endothelial cells decrease during the follow-up period.

CONCLUSION

Repeated CXL can induce an excessive corneal flattening more pronounced during the first years of follow-up followed by stabilization thereafter.

Для цитирования: Grentzelos Michael A, Voulgari Nafsika, Giacuzzo Clarice, Droutsas Konstantinos, Kymionis George D. Evolution of corneal flattening after repeated corneal cross-linking during a 6-year follow-up.. European journal of ophthalmology. 2020. DOI: 10.1177/1120672120945662.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.