MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s256629

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2020

Evaluation of Corneal Biomechanical Parameters in Psoriasis Patients: A Controlled Study.

Edris Noha A, Arfeen Shaimaa A, Mosaad Rana, Nassar Ghada A

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate corneal biomechanical parameters with an ocular response analyzer (ORA) in patients with psoriasis and compare these parameters with age-matched control subjects.

STUDY

DESIGN

This was a cross-sectional observational case-control study.

METHODS

Thirty eyes of 15 psoriasis patients were included in the study and compared with 30 eyes of 15 control subjects. Corneal biomechanical properties were calculated by ORA. Central corneal thickness (CCT) was measured by anterior-segment optical coherence tomography. The main outcome measures were corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and Goldmann-correlated IOP (IOPg). For dry-eye evaluation, Schirmer's test was used.

RESULTS

Mean CH in the psoriasis group was 10.20±1.55 mmHg and in the control group 10.66±1.36 mmHg (p=0.215). Mean CRF in the psoriasis group was 9.76±1.60 mmHg and in the control group 10.97±1.42 mmHg (p=0.003). Mean IOPcc in the psoriasis group was 14.84±3.43 mmHg and in the control group 16.67±3.17 mmHg (p=0.035). Mean IOPg in the psoriasis group was 13.92±3.35 mmHg and in the control group 16.62±3.10 mmHg (p=0.002). Mean CCT in the psoriasis group was 543.90±37.27 µm and in the control group 551.23±28.63 µm (p=0.392). Schirmer's test results in the psoriasis group were 11.4±1.57 mm/5 min and in the control group 17.5±1.52 mm/5 min (p<0.001).

CONCLUSION

Psoriasis affects corneal biomechanical properties with statistically significantly lower corneal biomechanics than normal. CH correlates negatively with disease activity. These corneal biomechanical changes should be considered when determining IOP values and during corneal evaluation for keratoconus-suspected patients.

Для цитирования: Edris Noha A, Arfeen Shaimaa A, Mosaad Rana, Nassar Ghada A. Evaluation of Corneal Biomechanical Parameters in Psoriasis Patients: A Controlled Study.. Clinical ophthalmology (Auckland, N.Z.). 2020. DOI: 10.2147/opth.s256629.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.