DOI 10.1097/ico.0000000000002307

Медицинская библиотека · Cornea · 2020

Scheimpflug Corneal Densitometry Changes After the Intrastromal Corneal Ring Segment Implantation.

Sedaghat Mohammad-Reza, Momeni-Moghaddam Hamed, Heravian Javad, Belin Michael W, Ambrósio Renato, Gheysari-Alishahi Tayebe, Ghavami Seyyed Hossein

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate the changes in corneal backward scattering using Scheimpflug tomography (densitometry) 6 months after intrastromal corneal ring segments (Keraring) implant for keratoconus and to correlate with clinical results.

METHODS

Along with standard ophthalmic examination, Scheimpflug tomography using Pentacam HR was performed to document corneal densitometry and corneal shape. A densitometry map was displayed using grayscale units (GSUs) ranging from 0 to 100 (minimum to maximum light scattering) in 4 concentric annuluses: central 2-, 2- to 6-, 6- to 10-, 10- to 12-, and total 12-mm corneal diameter and at 3 different depths: anterior 120 μm, posterior 60 μm, middle (varying accordingly to the total thickness), and total thickness.

RESULTS

The changes in mean corneal densitometry values for anterior, central, and posterior layers were 3.82 ± 3.13, 2.70 ± 1.78, and 1.68 ± 1.52 GSU, respectively, and for annuluses of 0 to 2, 2 to 6, 6 to 10, and 10 to 12 mm were 2.96 ± 2.60, 4.53 ± 2.28, 2.09 ± 1.74, and 0.45 ± 3.93 GSU, respectively. The mean values increased for all corneal layers (P < 0.05), except in the peripheral 10- to 12-mm annulus (P> 0.05). The highest increase was in the annulus 2 to 6 mm of the anterior layer (5.72 ± 3.70 GSU). Changes in the mean densitometry showed a significant correlation with the mean of average keratometry changes only for the front corneal surface and changes in the Q-values for both corneal surfaces in the 2- to 6-mm annulus for all layers.

CONCLUSIONS

Significant increase in the corneal densitometry mainly in the anterior 2- to 6-mm annulus of the cornea is associated with the position of the ring segment implant. More studies are needed to elucidate the relevance of such findings.

Для цитирования: Sedaghat Mohammad-Reza, Momeni-Moghaddam Hamed, Heravian Javad, Belin Michael W, Ambrósio Renato, Gheysari-Alishahi Tayebe, Ghavami Seyyed Hossein. Scheimpflug Corneal Densitometry Changes After the Intrastromal Corneal Ring Segment Implantation.. Cornea. 2020. DOI: 10.1097/ico.0000000000002307.