DOI 10.1016/j.ijcard.2017.09.172
Quality control of regional wall motion analysis in stress Echo 2020.
Аннотация
BACKGROUND
The trial "Stress Echo (SE) 2020" evaluates novel applications of SE beyond coronary artery disease. The aim of the study was control quality and harmonize reading criteria.
METHODS
One reader from 78 centers of the SE 2020 network asked for credentials to read a set of 20 SE video-clips selected by the core lab. All aspiring centers met the pre-requisite of high-volume and the years of experience in SE ranged from 5 to 31years (mean value 18years). The diagnostic gold standard was a reading by the core lab. The a priori determined pass threshold was 18/20 (≥90%).
RESULTS
Of the initial 78 who started, 57 completed the first attempt: individual readers' score on first attempt ranged from 07/20 to 20/20 (accuracy from 35% to 100%, mean 78.7±13%) and 44 readers passed it. There was a very poor correlation between years of experience and the reader's score on first attempt (r=-0.161, p=0.231). Of the 13 readers who failed the first attempt, 12 took it again after the web-based session and their accuracy improved (74% vs. 96%, p<0.001). The kappa inter-observer agreement before and after web-based training was 0.59 on first attempt and rose to 0.91 on the last attempt.
CONCLUSIONS
In SE reading, the volume of activity or years of experience is not synonymous with diagnostic quality. Qualitative analysis and operator-dependence can become a limiting weakness in clinical practice, in the absence of strict pathways of learning, credentialing and audit.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.