The American journal of cardiology · 2011
Relation of ventricular tachycardia/fibrillation to beta-blocker dose maximization guided by pacing mode analysis in nonpacemaker-dependent patients with implantable cardioverter-defibrillator.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Deftereos Spyridon, Giannopoulos Georgios, Kossyvakis Charalampos, Kaoukis Andreas, Raisakis Konstantinos, Panagopoulou Vasiliki, Ntzouvara Olga, Perpinia Anastasia, Rentoukas Ilias, Pyrgakis Vlasios, Manolis Antonios S, Stefanadis Christodoulos
Аннотация
We hypothesized that uptitration of β blockade and adjustment of pacing parameters to achieve a prevalence of single chamber atrial inhibited rate-responsive (AAIR) pacing in patients with dual-chamber implantable cardioverter--defibrillators (ICDs) would result in maximization of β-blocker dosage and thus decrease appropriate ICD therapies. We included patients with ischemic or dilated cardiomyopathy and implanted ICDs without contraindications to β blockers and atrioventricular conduction disturbances. Two 6-month periods were compared: clinically guided phase (pacing function set at back-up dual-chamber rate-responsive pacing mode at a lower rate of about 40 beats/min) and pacing-guided phase, during which β-blocker dosage was titrated with a target of achieving >90% AAIR pacing (lower rate 60 beats/min). Sixty-one patients (64.2 ± 8.3 years old) were included. During the pacing-guided phase the target of ≥90% AAIR pacing was achieved in 80.3% of patients. Mean metoprolol dose during the clinically guided phase was 96.7 ± 29.4 versus 127.0 ± 39.6 mg/day in the pacing-guided phase (p <0.001). Appropriate ICD therapies were recorded in 35 patients (57.4%) during the clinically guided phase versus 20 (32.8%) during the pacing-guided phase (p <0.001; 1.15 and 0.48 appropriate ICD therapies per patient, respectively, p <0.001). In multivariate analysis, AAIR pacing and β-blocker dose were inversely related to appropriate ICD therapies. In conclusion, a pacing-guided approach for maximizing β-blocker doses guided by maximizing AAIR pacing in patients with ICDs may be beneficial compared to the conventional strategy. This pacing-guided approach led to higher daily β-blocker doses, which were correlated to fewer appropriate ICD therapies.