Effects of mechanical left ventricular unloading by Impella on left ventricular dynamics in high-risk and primary percutaneous coronary intervention patients.

Remmelink Maurice, Sjauw Krischan D, Henriques José P S, de Winter Robbert J, Vis Marije M, Koch Karel T, Paulus Walter J, de Mol Bas A J M, Tijssen Jan G P, Piek Jan J, Baan Jan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We studied online left ventricular (LV) dynamic effects of mechanical LV unloading directly after percutaneous coronary intervention (PCI).

BACKGROUND

Limited clinical information is available on the direct LV dynamic consequences of LV unloading in patients undergoing high-risk PCI and primary PCI for acute ST-elevation myocardial infarction.

METHODS

The effects of the Impella LP2.5 device on LV dynamics were studied in 11 patients (elective high-risk PCI, n = 6; primary PCI, n = 5). LV pressure and volume were continuously assessed by a pressure-conductance catheter at 4 different support levels of the Impella, from 0 L/min at baseline to 2.5 L/min at maximal support.

RESULTS

The response to increased LV unloading was not different between both groups of patients. The pooled data showed no change on global and systolic LV function during increased LV unloading, while diastolic function showed improvement as indicated by an increased LV compliance in all patients. There was a decrease in end-diastolic pressure from 22 +/- 12 to 13 +/- 9 mm Hg (P = 0.0001), in end-diastolic elastance from 0.134 +/- 0.060 to 0.091 +/- 0.064 mm Hg/mL (P = 0.009), and in end-diastolic wall stress from 84 +/- 50 to 47 +/- 39 mm Hg (P = 0.004).

CONCLUSIONS

LV unloading decreases end-diastolic wall stress and improves diastolic compliance dose-dependently. Our results indicate beneficial LV unloading effects of Impella during high-risk and primary PCI.

Для цитирования: Remmelink Maurice, Sjauw Krischan D, Henriques José P S, de Winter Robbert J, Vis Marije M, Koch Karel T, Paulus Walter J, de Mol Bas A J M, Tijssen Jan G P, Piek Jan J, Baan Jan. Effects of mechanical left ventricular unloading by Impella on left ventricular dynamics in high-risk and primary percutaneous coronary intervention patients.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2010. DOI: 10.1002/ccd.22263.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.