m+Medelevator.RU
← Поиск публикаций
Journal of the American College of Cardiology · 2009

Optimizing hemodynamics in heart failure patients by systematic screening of left ventricular pacing sites: the lateral left ventricular wall and the coronary sinus are rarely the best sites.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Derval Nicolas, Steendijk Paul, Gula Lorne J, Deplagne Antoine, Laborderie Julien, Sacher Frederic, Knecht Sebastien, Wright Matthew, Nault Isabelle, Ploux Sylvain, Ritter Philippe, Bordachar Pierre, Lafitte Stephane, Réant Patricia, Klein George J, Narayan Sanjiv M, Garrigue Stephane, Hocini Mélèze, Haissaguerre Michel, Clementy Jacques, Jaïs Pierre

Аннотация

OBJECTIVES: We sought to evaluate the impact of the left ventricular (LV) pacing site on hemodynamic response to cardiac resynchronization therapy (CRT).

BACKGROUND: CRT reduces morbidity and mortality in heart failure patients. However, 20% to 40% of eligible patients may not fully benefit from CRT device implantation. We hypothesized that selecting the optimal LV pacing site could be critical in this issue.

METHODS: Thirty-five patients with nonischemic dilated cardiomyopathy referred for CRT device implantation were studied. Intraventricular dyssynchrony and latest activated LV wall were defined by tissue Doppler imaging analysis before the study. Eleven predetermined LV pacing sites were systematically assessed in random order: basal and mid-cavity (septal, anterior, lateral, inferior), apex, coronary sinus (CS), and the endocardial site facing the CS pacing site. For each patient, +dP/dT(max), -dP/dT(min), pulse pressure, and end-systolic pressure during baseline (AAI) and DDD LV pacing were compared. Two atrioventricular delays were tested.

RESULTS: Major interindividual and intraindividual variations of hemodynamic response depending on the LV pacing site were observed. Compared with baseline, LV DDD pacing at the best LV position significantly improved +dP/dT(max) (+31 +/- 26%, p < 0.001) and was superior to pacing the CS (+15 +/- 23%, p < 0.001), the lateral LV wall (+18 +/- 22%, p < 0.001), or the latest activated LV wall (+11 +/- 17%, p < 0.001).

CONCLUSIONS: The pacing site is a primary determinant of the hemodynamic response to LV pacing in patients with nonischemic dilated cardiomyopathy. Pacing at the best LV site is associated acutely with fewer nonresponders and twice the improvement in +dP/dT(max) observed with CS pacing.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты