The American journal of cardiology · 2007

Utility of isoproterenol in unmasking latent escape rhythm in pacemaker dependent patients undergoing pacemaker replacement.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chihrin Stephen M, Mohamed Uwais, Yee Raymond, Gula Lorne J, Klein George J, Skanes Allan C, Krahn Andrew D

Аннотация

Pacemaker generator replacement in dependent patients may be managed with a bridging temporary pacing lead or by replacing the generator very expediently. The 2 options involve a small risk, and temporary pacing introduces additional cost. This study was conducted to explore the utility of a graduated rate-decrease protocol with isoproterenol support in unmasking an intrinsic rhythm that would obviate the 2 strategies. The protocol was used in 100 consecutive pacemaker-dependent patients (mean age 74.4 +/- 13.7 years, 56% men) who underwent permanent pacemaker replacement. Device lower rates were decremented in 1-minute intervals to 60, 50, 40, and 30 beats/min. If no intrinsic rhythm of > or =30 beats/min was observed after 1 minute, isoproterenol was infused at 1 microg/min for 2 minutes, followed by 2 microg/min for 2 minutes. Of the 100 patients, 59 demonstrated intrinsic rhythm during pacing step-down alone. Of the remaining 41 patients, 28 (68.3%) demonstrated intrinsic rhythm during isoproterenol infusion. The escape rhythm was junctional in 29%, idioventricular in 23%, conducted atrial fibrillation in 16%, and sinus in 15%. Only 13 of 100 patients (13%) failed to demonstrate adequate intrinsic rhythm after the protocol. In conclusion, this suggests that a standardized protocol to elicit an underlying rhythm in patients previously assessed as pacemaker dependent effectively minimizes the need for temporary pacing during device replacement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты