m+Medelevator.RU
← Поиск публикаций
Eye & contact lens · 2023

Intraobserver Repeatability Assessment of the S390L Firefly WDR Slitlamp in Patients With Dry Eye Disease: Objective, Automated, and Noninvasive Measures.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ballesteros-Sánchez Antonio, Gargallo-Martínez Beatriz, Gutiérrez-Ortega Ramón, Sánchez-González José-María

Аннотация

OBJECTIVES: To assess the intraobserver repeatability of automated, objective, and noninvasive measures obtained with the S390L Firefly WDR slitlamp.

METHODS: This cross-sectional study included 50 eyes of patients with dry eye disease with a mean age of 55.06±12.96 years. Three consecutively repeated measures of the following variables were obtained: first noninvasive break-up time (F-NIBUT), average noninvasive break-up time (A-NIBUT), tear meniscus height, tear meniscus area (TMA), nasal ciliary hyperemia (NCIH), temporal ciliary hyperemia (TCIH), nasal conjunctival hyperemia (NCOH), temporal conjunctival hyperemia (TCOH), upper loss area meibomian gland (U-LAMG), lower loss area meibomian gland (L-LAMG), upper meibomian gland dysfunction grade (U-MGD grade), and lower meibomian gland dysfunction grade (L-MGD grade). Intraobserver repeatability was estimated with coefficient of variation (CoV), intrasubject standard deviation (SD) (S w ), and Bland-Altman plots.

RESULTS: All variables showed no statistically significant differences in the repeated-measures analysis except for L-MGD grade ( P =0.045). F-NIBUT and A-NIBUT obtained the highest CoV with an average value of 0.48±0.41 [0.02-1.00] and 0.34±0.25 [0.02-1.00], respectively. The remaining variables showed CoVs between 0.04±0.11 [0.00-0.43] and 0.18±0.16 [0.00-0.75]. A-NIBUT, TMA, NCOH, and L-LAMG obtained an S w of 2.78s, 0.21 mm 2 , <0.001, and 4.11%, respectively. Bland-Altman plots showed a high level of agreement between pairs of repeated measures.

CONCLUSION: The S390L Firefly WDR slitlamp has moderate intraobserver repeatability for F-NIBUT and A-NIBUT, which suggests that F-NIBUT and A-NIBUT are tests with high variability. The remaining variables show satisfactory intraobserver repeatability.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты