m+Medelevator.RU
← Поиск публикаций
Chinese medical journal · 2012

Radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia guided by magnetic navigation system: a prospective randomized comparison with conventional procedure.

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Yu-Xiao, Lu Cai-Yi, Xue Qiao, Li Ke, Yan Wei, Zhou Sheng-Hua

Аннотация

BACKGROUND: Atrioventricular nodal reentrant tachycardia (AVNRT) is one of the most common paroxysmal supraventricular tachyarrhythmias. The aim of the study was to prospectively compare the characteristics of radiofrequency catheter ablation of AVNRT guided by a magnetic navigation system with the conventional procedure.

METHODS: Patients with AVNRT diagnosed by electrophysiological tests were randomized into two groups. In the conventional technique group (CMT), a common 4-mm-tip quadrapolar temperature-controlled ablation catheter was used. In the magnetic navigation system guidance group (MNS), a magnetic 4-mm-tip quadrapolar temperature-controlled ablation catheter was used. The following parameters were collected and compared between the two groups: ablation procedure time, patient fluoroscopy time, operator fluoroscopy time, energy delivery numbers, maximal energy per deployment, success rate, complication rate and operative cost.

RESULTS: Forty patients were enrolled and randomized into CMT and MNS groups. The age, gender, tachycardia history and basic cardiovascular diseases of the two groups were comparable (P > 0.05). All procedures were conducted successfully without complications. No tachycardia recurred during the follow-up period of (9.3 ± 2.6) months. In the MNS group, the patient and operator fluoroscopy times ((11.5 ± 4.3) min, (4.2 ± 1.5) min), energy delivery numbers (3.2 ± 0.9), and maximal energy per deployment ((16.9 ± 3.4) W) were shorter or lower than those of the CMT group ((14.3 ± 6.2) min, (13.6 ± 3.5) min, 6.3 ± 2.1, (23.7 ± 1.3) W, respectively) (P < 0.05). But the operative cost for the MNS group was higher than that of the CMT group (P < 0.01).

CONCLUSION: Magnetic navigation system guided radiofrequency catheter ablation of AVNRT has the advantages of shorter fluoroscopy time and lower energy delivery numbers and maximal energy per deployment compared to the present conventional ablation technique.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты