m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2010

Atrial substrate properties and outcome of catheter ablation in patients with paroxysmal atrial fibrillation associated with diabetes mellitus or impaired fasting glucose.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chao Tze-Fan, Suenari Kazuyoshi, Chang Shih-Lin, Lin Yenn-Jiang, Lo Li-Wei, Hu Yu-Feng, Tuan Ta-Chuan, Tai Ching-Tai, Tsao Hsuan-Ming, Li Cheng-Hung, Ueng Kuo-Chang, Wu Tsu-Juey, Chen Shih-Ann

Аннотация

Diabetes mellitus has been reported to be an independent risk factor of atrial fibrillation (AF). The present study investigated the atrial substrate properties and clinical outcome of catheter ablation in patients with paroxysmal AF and abnormal glucose metabolism. A total of 228 patients with paroxysmal AF who had undergone catheter ablation for the first time were enrolled. An abnormal glucose metabolism (n = 65) was defined as diabetes mellitus or an impaired fasting glucose. We analyzed the clinical and electrophysiologic characteristics in, and the clinical outcome of, patients with AF with and without an abnormal glucose metabolism. The right atrial (107.2 ± 15.4 vs 96.0 ± 16.5 ms, p < 0.001) and left atrial (108.4 ± 22.3 vs 94.0 ± 17.5 ms, p < 0.001) total activation times were significantly longer in the patients with AF and an abnormal glucose metabolism than in those without an abnormal metabolism. Furthermore, the right atrial (1.46 ± 0.61 vs 2.00 ± 0.70 mV, p < 0.001) and left atrial (1.48 ± 0.74 vs 2.05 ± 0.78 mV, p < 0.001) bipolar voltages were significantly lower in those with AF and an abnormal glucose metabolism than in those without. The AF recurrence rate was also greater in the patients with an abnormal glucose metabolism (18.5% vs 8.0%, p = 0.022) than in those without. The follow-up duration was 18.8 ± 6.4 months. In conclusion, an abnormal glucose metabolism affects the biatrial substrate properties with an intra-atrial conduction delay, decreased voltage, and greater recurrence rate after catheter ablation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты