The feasibility of fully automated pacemaker advise in treating atrial tachyarrhythmias.

Ruiter Jacob H, Mulder Elles, Schuchert Andreas, Burri Haran, Stühlinger Markus C, Hartikainen Juha, Sermasi Sergio, Vlasínová Jitka, Mairesse Georges H, Bub Eberhard, Lewalter Thorsten, T-STAR Study Group

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Modern pacemakers continuously store significant cardiac-related events. Interpreting these data and reprogramming the pacemaker can be time-consuming and demands expert knowledge. A software-based expert system, the therapy advisor (TA), was developed, which analyzes stored data and provides reprogramming recommendations. This study addresses whether pacemaker experts consider the messages that are automatically generated appropriate in the management of atrial tachyarrhythmias/atrial fibrillation (AT/AF).

METHODS

This observational, international, multicenter study follows 150 patients with suspected or documented atrial arrhythmias who received a dual-chamber pacemaker (model Vitatron T-70, Medtronic Inc., Minneapolis, MN, USA) incorporating the TA. The TA summarizes technical and clinical data stored in the pacemaker into key messages and may suggest programming changes. Twenty-five cardiologists examined their patients per normal practice during two follow-up visits. They reported the therapy changes they deemed necessary without initially reviewing the TA messages. Next, they rated their satisfaction with and the clinical relevance of the TA messages and recorded the final therapy changes.

RESULTS

The TA generated (mostly AT/AF-related) main observations in 49% and programming advice in 33% of the patients. The experts rated 95% of the TA messages as satisfactory and deemed therapy changes necessary in roughly half the patients. Pacemaker changes in AT/AF therapy or general settings were prompted primarily by the diagnostic information stored in the device. Medication changes were mostly led by the symptoms reported by the patient.

CONCLUSION

This study demonstrates that experienced cardiologists agree with 95% of the observations and programming suggestions that the TA automatically generates.

Для цитирования: Ruiter Jacob H, Mulder Elles, Schuchert Andreas, Burri Haran, Stühlinger Markus C, Hartikainen Juha, Sermasi Sergio, Vlasínová Jitka, Mairesse Georges H, Bub Eberhard, Lewalter Thorsten, T-STAR Study Group. The feasibility of fully automated pacemaker advise in treating atrial tachyarrhythmias.. Pacing and clinical electrophysiology : PACE. 2010. DOI: 10.1111/j.1540-8159.2010.02689.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.