Nuclear medicine communications · 2024
Diagnostic value of [ 68 Ga]Ga-Pentixafor PET/CT in malignant melanoma: a pilot study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Manafi-Farid Reyhaneh, Mahini Marjan, Mirshahvalad Seyed Ali, Fallahi Babak, Fard-Esfahani Armaghan, Emami-Ardekani Alireza, Eftekhari Mohammad, Mousavi Seied Asadollah, Beiki Davood
Аннотация
OBJECTIVE: To evaluate the diagnostic value of [ 68 Ga] Ga-Pentixafor in malignant melanoma patients.
METHODS: In this prospective study, patients with histology-proven melanoma were included and underwent [ 18 F]fluoro-D-glucose ([ 18 F]FDG) and [ 68 Ga] Ga-Pentixafor PET/computed tomography (CT) within a week. Suspicious lesions were interpreted as benign vs. malignant, and the corresponding semi-quantitative PET/CT parameters were recorded and compared.
RESULTS: Twelve consecutive melanoma patients (mean age: 60 ± 6) were included. Two patients were referred for initial staging, two for detecting recurrence and eight for evaluating the extent of metastases. Overall, [ 18 F]FDG PET/CT showed 236 tumoral lesions, including two primary tumors, two recurrent lesions, 29 locoregional metastases and 203 distant metastases. In [ 68 Ga]Ga-Pentixafor PET/CT, 101 tumoral lesions were detected, including two primary tumors, one recurrence, 16 locoregional metastases and 82 distant metastases. Notably, a documented brain metastasis was only visualized on [ 68 Ga]Ga-Pentixafor PET/CT images. Compared with [ 18 F]FDG, [ 68 Ga]Ga-Pentixafor PET/CT provided a 42% detection rate. Regarding semi-quantitative measures, the intensity of uptake and tumor-to-background ratios were significantly lower on [ 68 Ga]Ga-Pentixafor PET/CT [average maximum standard uptake value (SUV max ) of 2.72 ± 1.33 vs. 11.41 ± 14.79; P value <0.001 and 1.17 ± 0.53 vs. 5.32 ± 7.34; P value <0.001, respectively].
CONCLUSION: When comparing [ 68 Ga]Ga-Pentixafor PET/CT with [ 18 F]FDG PET/CT, not only did [ 68 Ga]Ga-Pentixafor PET/CT detect fewer lesions, but the intensity of uptake and the TBRs were also lower on [ 68 Ga]Ga-Pentixafor PET/CT. Thus, our results may indicate a limited potential of this novel tracer in cutaneous melanoma patients compared to [ 18 F]FDG PET/CT. Given the lower TBRs, applying this radiotracer in radioligand therapies is also questionable.
METHODS: In this prospective study, patients with histology-proven melanoma were included and underwent [ 18 F]fluoro-D-glucose ([ 18 F]FDG) and [ 68 Ga] Ga-Pentixafor PET/computed tomography (CT) within a week. Suspicious lesions were interpreted as benign vs. malignant, and the corresponding semi-quantitative PET/CT parameters were recorded and compared.
RESULTS: Twelve consecutive melanoma patients (mean age: 60 ± 6) were included. Two patients were referred for initial staging, two for detecting recurrence and eight for evaluating the extent of metastases. Overall, [ 18 F]FDG PET/CT showed 236 tumoral lesions, including two primary tumors, two recurrent lesions, 29 locoregional metastases and 203 distant metastases. In [ 68 Ga]Ga-Pentixafor PET/CT, 101 tumoral lesions were detected, including two primary tumors, one recurrence, 16 locoregional metastases and 82 distant metastases. Notably, a documented brain metastasis was only visualized on [ 68 Ga]Ga-Pentixafor PET/CT images. Compared with [ 18 F]FDG, [ 68 Ga]Ga-Pentixafor PET/CT provided a 42% detection rate. Regarding semi-quantitative measures, the intensity of uptake and tumor-to-background ratios were significantly lower on [ 68 Ga]Ga-Pentixafor PET/CT [average maximum standard uptake value (SUV max ) of 2.72 ± 1.33 vs. 11.41 ± 14.79; P value <0.001 and 1.17 ± 0.53 vs. 5.32 ± 7.34; P value <0.001, respectively].
CONCLUSION: When comparing [ 68 Ga]Ga-Pentixafor PET/CT with [ 18 F]FDG PET/CT, not only did [ 68 Ga]Ga-Pentixafor PET/CT detect fewer lesions, but the intensity of uptake and the TBRs were also lower on [ 68 Ga]Ga-Pentixafor PET/CT. Thus, our results may indicate a limited potential of this novel tracer in cutaneous melanoma patients compared to [ 18 F]FDG PET/CT. Given the lower TBRs, applying this radiotracer in radioligand therapies is also questionable.