m+Medelevator.RU
← Поиск публикаций
Journal of arrhythmia · 2020

A prospective multicenter study of direct comparison of feasibility and safety of pulmonary vein isolation using the minimally interrupted apixaban between second-generation cryoballoon and radiofrequency ablation of paroxysmal atrial fibrillation: J-HIT apixaban.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yagishita Atsuhiko, Goya Masahiko, Iesaka Yoshito, Nitta Junichi, Takahashi Atsushi, Nagata Yasutoshi, Hachiya Hitoshi, Inaba Osamu, Inamura Yukihiro, Tanaka Yasuaki, Watanabe Keita, Tao Susumu, Shirai Yasuhiro, Yamamoto Tasuku, Shiohira Shinya, Akiyoshi Kikou, Sekigawa Masahiro, Maeda Shingo, Sasaki Takeshi, Takahashi Yoshihide, Kawabata Mihoko, Hirao Kenzo, J‐HIT investigators

Аннотация

BACKGROUND: The feasibility and safety of pulmonary vein isolation (PVI) using cryoballoon (CB) for paroxysmal atrial fibrillation (PAF) with minimally interrupted apixaban has not fully explored.

METHODS: In this multicenter, randomized prospective study, we enrolled patients with PAF undergoing CB or radiofrequency (RF) ablation with interrupted (holding 1 dose) apixaban. The primary composite end point consisted of bleeding events, including pericardial effusion and major bleeding requiring blood transfusion, or thromboembolic events at 4 weeks after ablation; secondary end points included early recurrence of AF and procedural duration.

RESULTS: A total of 250 patients underwent PVI (125 assigned to the RF ablation and 125 assigned to the CB ablation). The primary end point occurred in 1 patient in the CB ablation group (0.8%; 90% confidence interval [CI], 0.04 to 3.70) and 3 patients in the RF group (2.4%, P = .622; risk ratio, 0333; 90% CI, 0.05 to 2.20). All events were pericardial effusion, all of whom recovered after pericardiocentesis. Early recurrence of AF occurred in 4 patients (3.2%) in the RF group and in 6 patients (4.8%) in the CB group (P = .749). The procedural duration was shorter in the CB group than that in the RF group (136.5 ± 39.9 vs 179.5 ± 44.8 min, P < .001).

CONCLUSION: CB ablation with minimally interrupted apixaban was feasible and safe in patients with PAF undergoing PVI, which was equivalent to RF ablation.