MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jstrokecerebrovasdis.2020.104930

Медицинская библиотека · Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association · 2020

The additional value of an algorithm for atrial fibrillation at the stroke unit.

van der Maten Gerlinde, Plas Gerben J J, Meijs Matthijs F L, Brouwers Paul J A M, Brusse-Keizer Marjolein G J, den Hertog Heleen M

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: The rate of newly detected (paroxysmal) atrial fibrillation (AF) during inpatient cardiac telemetry is low. The objective of this study was to evaluate the additional diagnostic yield of an automated detection algorithm for AF on telemetric monitoring compared with routine detection by a stroke unit team in patients with recent ischemic stroke or TIA.

METHODS

Patients admitted to the stroke unit of Medisch Spectrum Twente with acute ischemic stroke or TIA and no history of AF were prospectively included. All patients had telemetry monitoring, routinely assessed by the stroke unit team. The ST segment and arrhythmia monitoring (ST/AR) algorithm was active, with deactivated AF alarms. After 24 h the detections were analyzed and compared with routine evaluation.

RESULTS

Five hundred and seven patients were included (52.5% male, mean age 70.2 ± 12.9 years). Median monitor duration was 24 (interquartile range 22-27) h. In 6 patients (1.2%) routine analysis by the stroke unit team concluded AF. In 24 patients (4.7%), the ST/AR Algorithm suggested AF. Interrater reliability was low (κ, 0.388, p < 0.001). Suggested AF by the algorithm turned out to be false positive in 11 patients. In 13 patients (2.6%) AF was correctly diagnosed by the algorithm. None of the cases detected by routine analysis were missed by the algorithm.

CONCLUSIONS

Automated AF detection during 24-h telemetry in ischemic stroke patients is of additional value to detect paroxysmal AF compared with routine analysis by the stroke unit team alone. Automated detections need to be carefully evaluated.

Для цитирования: van der Maten Gerlinde, Plas Gerben J J, Meijs Matthijs F L, Brouwers Paul J A M, Brusse-Keizer Marjolein G J, den Hertog Heleen M. The additional value of an algorithm for atrial fibrillation at the stroke unit.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2020. DOI: 10.1016/j.jstrokecerebrovasdis.2020.104930.