m+Medelevator.RU
← Поиск публикаций
Journal of cardiovascular electrophysiology · 2020

Evaluation of higher power delivery during RF pulmonary vein isolation using optimized and contiguous lesions.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kyriakopoulou Maria, Wielandts Jean-Yves, Strisciuglio Teresa, El Haddad Milad, Pooter Jan De, Almorad Alexandre, Hilfiker Gabriela, Phlips Thomas, Unger Philippe, Lycke Michelle, Vandekerckhove Yves, Tavernier Rene, Duytschaever Mattias, Knecht Sebastien

Аннотация

AIMS: "CLOSE"-guided pulmonary vein isolation (PVI) is based on contiguous (≤6 mm) and optimized radiofrequency (RF) ablation lesions (ablation index [AI] ≥ 400 posteriorly and ≥ 550 anteriorly]. However, the optimal RF power to reach the desired AI is unknown. Therefore we evaluated the efficiency of an ablation strategy using higher power (40 W) during a first "CLOSE"-guided PVI.

METHODS: Eighty consecutive patients undergoing "CLOSE"-guided PVI for symptomatic paroxysmal atrial fibrillation were ablated with 40 W (group A). Results were compared with 105 consecutive patients enrolled in the "CLOSE to CURE"-study and were ablated using the same protocol with 35 W (group B).

RESULTS: In group A, ablation was associated with shorter ablation procedure time (91 vs 111 minutes; P < .001), shorter fluoroscopy time (5 vs 11 minutes; P < .001), shorter PVI time (48 vs 64 minutes; P < .001), shorter RF time (20 vs 28 minutes; P < .001), lower RF time per application (22 vs 29 seconds; P < .001), less RF applications (52 vs 58; P < .001), and less catheter dislocations (1 vs 2; P = .002). The impedance drop (12 vs 13 Ω; P = .192), first-pass isolation rate (99% vs 93%; P = .141) and acute reconnection rate (6% vs 4%; P > .733) were similar in both groups (groups A and B, respectively). No complications occurred. In group A, a gastroscopy-performed in five patients with esophageal temperature rise more than 42°C-did not reveal any esophageal lesion. Postprocedural recurrence of atrial tachyarrhythmia at 1 year was not significantly different between both groups.

CONCLUSIONS: Using the "CLOSE"-protocol, increased power increases the efficiency of PVI without compromising patients' safety.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты