m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2020

Long-term outcomes after second-generation cryoballoon ablation of paroxysmal atrial fibrillation - Feasibility of a single short freeze strategy without bonus applications.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hara Satoshi, Miyazaki Shinsuke, Hachiya Hitoshi, Kajiyama Takatsugu, Watanabe Tomonori, Nakamura Hiroaki, Tada Hiroshi, Iesaka Yoshito

Аннотация

BACKGROUND: A paucity of data exists about long-term outcomes after second-generation cryoballoon ablation (2nd-CBA), and the feasibility of short freeze strategies remains under debate. We assessed the long-term follow-up outcomes.

METHODS: This study included 186 paroxysmal atrial fibrillation (PAF) patients (62 ± 11 years, 136 men) who underwent 2nd-CBAs with a 28-mm balloon and single 3-min freeze strategy without bonus applications. Fourteen-day consecutive monitoring was performed to detect early AF recurrences (ERAFs).

RESULTS: Overall, 713/736(96.9%) PVs were isolated with CBs. The total number of applications/patient was 5.3 ± 1.5. The total procedure and fluoroscopic times were 79.9 ± 28.1 and 24.4 ± 14.2 min. Asymptomatic right phrenic nerve injury occurred in 11 patients, however, all recovered during the follow-up. A total of 76(41.7%) patients experienced ERAFs. During a median 45.0 [30.0-51.0] month follow-up, the single procedure AF freedom was 76.1, 73.5, 70.5, and 63.7% at 1, 2, 3, and 4 years, respectively. At a median of 7.0 [4.0-12.0] months after the initial procedure, 35 (18.8%) patients underwent second procedures, and 106/137 (77.4%) PVs were still isolated. The multiple procedure AF freedom was 91.7, 89.3, 86.8, and 81.3% at 1, 2, 3, and 4 years, respectively. A Cox's proportional hazards model determined that the presence of ERAF was associated with a greater risk of recurrence after the last procedure (Hazard ratio = 2.830; 95% confidence interval = 1.173-6.833; p = 0.021). The percentage of continuation of anticoagulation therapy after the initial procedure was 33.1, 23.5, 21.7, and 21.7% at 1, 2, 3, and 4 years, respectively.

CONCLUSIONS: Our long-term follow-up data demonstrated the feasibility of a single short freeze strategy in PAF patients.