m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2020

Safety and outcome of very high-power short-duration ablation using 70 W for pulmonary vein isolation in patients with paroxysmal atrial fibrillation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kottmaier Marc, Popa Miruna, Bourier Felix, Reents Tilko, Cifuentes Jairo, Semmler Verena, Telishevska Martha, Otgonbayar Ulamnemekh, Koch-Büttner Katharina, Lennerz Carsten, Bartkowiak Marcin, Kornmayer Marielouise, Rousseva Elena, Brkic Amir, Grebmer Christian, Kolb Christoph, Hessling Gabriele, Deisenhofer Isabel

Аннотация

AIMS: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) in patients with paroxysmal atrial fibrillation (PAF) is effective but hampered by pulmonary vein reconnection due to insufficient ablation lesions. High-power delivery over a short period of time (HPSD) in RFA is stated to create more efficient lesions. The aim of this study was to compare intraprocedural safety and outcome of HPSD ablation to conventional power settings in patients undergoing PVI for PAF.

METHODS AND RESULTS: We included 197 patients with PAF that were scheduled for PVI. An ablation protocol with 70 W and a duration cut-off of 7 s at the anterior left atrium (LA) and 5 s at the posterior LA (HPSD group; n = 97) was compared to a conventional power protocol with 30-40 W for 20-40 s (standard group; n = 100) in terms of periprocedural complications and a 1-year outcome. The HPSD group showed significantly less arrhythmia recurrence during 1-year follow-up with 83.1% of patients free from atrial fibrillation compared to 65.1% in the standard group (P < 0.013). No pericardial tamponade, periprocedural thromboembolic complications, or atrio-oesophageal fistula occurred in either group. Mean radiofrequency time (12.4 ± 3.4 min vs. 35.6 ± 12.1 min) and procedural time (89.5 ± 23.9 min vs. 111.15 ± 27.9 min) were significantly shorter in the HPSD group compared to the standard group (both P < 0.001).

CONCLUSION: High-power short-duration ablation demonstrated a comparable safety profile to conventional ablation. High-power short-duration ablation using 70 W for 5-7 s leads to significantly less arrhythmia recurrences after 1 year. Radiofrequency and procedural time were significantly shortened.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты